iLegend Series Container Data Center Solution

Support 3-8 cabinets, capacity up to 70kW. Specially developed and designed for outdoor use scenarios. It's a 20ft/40ft standard container for transportation, factory prefabricated, and ready for operation after arrival. With a protection rating of IP55, it can be used in any harsh environment. ( Watch the introduction video on YouTube )


Email Us
  • Product description
  • Features
  • Specifications
  • Certification
  • Download
    • Commodity name: iLegend Series Container Data Center Solution
    • Commodity ID: 1063516320382472192

    Support 3-8 cabinets, capacity up to 70kW. Specially developed and designed for outdoor use scenarios. It's a 20ft/40ft standard container for transportation, factory prefabricated, and ready for operation after arrival. With a protection rating of IP55, it can be used in any harsh environment.

    Support 3-8 cabinets, capacity up to 70kW. Specially developed and designed for outdoor use scenarios. It's a 20ft/40ft standard container for transportation, factory prefabricated, and ready for operation after arrival. With a protection rating of IP55, it can be used in any harsh environment. ( Watch the introduction video on YouTube )

  • 1. Factory prefabricated

     

     

    2. 20ft/40ft standard container

     

     

    3. All-in-one secure and reliable

     

     

    4. IP55,automatic fire extinguishing system

     

     

  • iLegend Container Data Center Product Specification
    Unit 40ft layout All-In-One solution 20ft layout All-In-One solution
    Cabinet System Size of IT cabinet(W×D×H)mm 600×1200×2000 600×1200×2000
    Num. of IT cabinet(pcs) 8 3
    Power of each cabinet(kW) 6/9(High density) 6/9(High density)
    Total power(kW) 48/72(High density) 18/27(High density)
    Power and Distribution
    System
    Power supply system  250A Dual input/ATS optional; 380/400/415V, 50/60Hz, 3Ph+N+PE; input lightning protection 8/20us, In=20kA, Imax=40kA   125A Dual input/ATS optional; 380/400/415V, 50/60Hz, 3Ph+N+PE; input lightning protection 8/20us, In=20kA, Imax=40kA  
    UPS Modular Online UPS 90~150kVA Modular Online UPS 40~90kVA
    Battery back-up time In-row battery cabinet, the number of battery and capacity can be selected according to project requirements
    PDU 16 port IEC PDU(C13*12+C19*4),32A
    Cooling System Cooling method  Default installation of 25kW air-cooled inverter in-row air conditioner(300mm wide)
    Monitoring System Power and environment system Monitoring host can realize the centralized monitoring of integrated power distribution cabinet, UPS, air conditioning, access control, video, fire, etc., and support sound and light, telephone, WeChat, SMS, e-mail multiple alarm methods
    Access control Support IC card + password + fingerprint three-in-one access control system, optional face recognition
    Local Display Support 10.1 inch touch screen, support local touch screen, client, remote Web, mobile app and other display methods
    Fire Prevention System  Fire extinguishing system Automatic flooding fire extinguishing system, cold/hot aisles are equipped with smoke and temperature sensor, automatic control of fire gas release , support for sound and light, gas release indicator and other warning methods, support for manual emergency opening of the fire extinguishing system (optional Pipe fire extinguishers)
    Fire extinguishing gas FM200/HFC-227ea (Novec 1230 optional)
    Container Structure  Container size(H×W×L)mm 40ft:2896×2438×12192 20ft:2896×2438×6058
    Weight of container(T) 8 4
    Container load-bearing(T) 15 7
    Container protection Waterproof, dustproof, anti-mold, protection grade:IP55
    Operation Environment Ambient temperature(℃) -40~50(-20 ℃ below require optional low temperature components and water pipes need to do insulation treatment)
    Altitude(m) More than 1000m need to be derated

Features

Specifications

Certification

Download

1. Factory prefabricated

 

 

2. 20ft/40ft standard container

 

 

3. All-in-one secure and reliable

 

 

4. IP55,automatic fire extinguishing system

 

 

iLegend Container Data Center Product Specification
Unit 40ft layout All-In-One solution 20ft layout All-In-One solution
Cabinet System Size of IT cabinet(W×D×H)mm 600×1200×2000 600×1200×2000
Num. of IT cabinet(pcs) 8 3
Power of each cabinet(kW) 6/9(High density) 6/9(High density)
Total power(kW) 48/72(High density) 18/27(High density)
Power and Distribution
System
Power supply system  250A Dual input/ATS optional; 380/400/415V, 50/60Hz, 3Ph+N+PE; input lightning protection 8/20us, In=20kA, Imax=40kA   125A Dual input/ATS optional; 380/400/415V, 50/60Hz, 3Ph+N+PE; input lightning protection 8/20us, In=20kA, Imax=40kA  
UPS Modular Online UPS 90~150kVA Modular Online UPS 40~90kVA
Battery back-up time In-row battery cabinet, the number of battery and capacity can be selected according to project requirements
PDU 16 port IEC PDU(C13*12+C19*4),32A
Cooling System Cooling method  Default installation of 25kW air-cooled inverter in-row air conditioner(300mm wide)
Monitoring System Power and environment system Monitoring host can realize the centralized monitoring of integrated power distribution cabinet, UPS, air conditioning, access control, video, fire, etc., and support sound and light, telephone, WeChat, SMS, e-mail multiple alarm methods
Access control Support IC card + password + fingerprint three-in-one access control system, optional face recognition
Local Display Support 10.1 inch touch screen, support local touch screen, client, remote Web, mobile app and other display methods
Fire Prevention System  Fire extinguishing system Automatic flooding fire extinguishing system, cold/hot aisles are equipped with smoke and temperature sensor, automatic control of fire gas release , support for sound and light, gas release indicator and other warning methods, support for manual emergency opening of the fire extinguishing system (optional Pipe fire extinguishers)
Fire extinguishing gas FM200/HFC-227ea (Novec 1230 optional)
Container Structure  Container size(H×W×L)mm 40ft:2896×2438×12192 20ft:2896×2438×6058
Weight of container(T) 8 4
Container load-bearing(T) 15 7
Container protection Waterproof, dustproof, anti-mold, protection grade:IP55
Operation Environment Ambient temperature(℃) -40~50(-20 ℃ below require optional low temperature components and water pipes need to do insulation treatment)
Altitude(m) More than 1000m need to be derated

Related Application Cases

Related Products

In-row Precision Cooling System(12.5-60kW)

Especially suitable for modular or container data centers. The series precision cooling system is configured high-efficiency variable frequency compressor, EC backward inclined centrifugal fan, and full variable frequency design, It's usually installed side by side with the server cabinet, creating an ideal operating environment for the key infrastructure of the data center.

iSmart Series Micro Data Center Solution

Also known as the mini data center, single cabinet capacity 3-7kVA. footprint is 0.72m2. INVT iSmart can be used in offices, the noise level is around 55dB after the door is closed, equivalent to a quiet office, does not affect work at all. All equipment is pre-installed and pre-commissioned in the factory, you can put into use directly.

iWit Series Single Row Data Center Solution

Suitable for IT rooms within 20-60㎡. Modular design, construction period 3-6 days. iWit has strong environmental adaptability, and the product can operate normally even in rooms with high ambient temperatures, no static floors, no refrigeration equipment, and outdoor cabinets.

iTalent Series Modular Data Center Solution

Support 6-50 cabinets, capacity up to 600kW. It applies to large indoor data centers, Adopts modular design, reliability up to 99.999%, average annual PUE=1.30, and supports automatic control and intelligent operation and maintenance. No need for professional machine room, can be installed directly on the concrete floor of the building.