undefined
undefined
undefined
undefined
+
  • undefined
  • undefined
  • undefined
  • undefined

HR11 Series Rack Online UPS 1-10kVA (220V/230V/240V)

The series 1:1 Rack Online UPS is the ideal choice for small data center. It supports in-built battery. And the 6kVA and 10kVA rack UPS of this series apply the advanced 3 level of technology, compatible with complicated load. The series has 1kVA, 2kVA, 3kVA, 6kVA, 10 kVA can be chosen. ( watch the introduction video on YouTube)


Email Us
  • Product description
  • Features
  • Specifications
  • Certification
  • Download
    • Commodity name: HR11 Series Rack Online UPS 1-10kVA (220V/230V/240V)
    • Commodity ID: 1063519302360649728

    The series 1:1 Rack Online UPS is the ideal choice for small data center. It supports in-built battery. And the 6kVA and 10kVA rack UPS of this series apply the advanced 3 level of technology, compatible with complicated load. The series has 1kVA, 2kVA, 3kVA, 6kVA, 10 kVA can be chosen.

    The series 1:1 Rack Online UPS is the ideal choice for small data center. It supports in-built battery. And the 6kVA and 10kVA rack UPS of this series apply the advanced 3 level of technology, compatible with complicated load. The series has 1kVA, 2kVA, 3kVA, 6kVA, 10 kVA can be chosen. ( watch the introduction video on YouTube)

  • Common features for 1-10kVA:

     

    ● Wide range of input voltage while input PF>99%

     

    ● 19” standard cabinet and battery cabinet

     

    ● Full protection of overvoltage, circuit short and over temperature

     

    ● LCD/LED display, monitoring all the operation status

     

    ● Automatic fan speed adjustment

     

    ● Abundant interface: RS232,USB, SNMP, Intelligent Card

     

    Unique features for 6-10kVA:

     

    ● High efficiency, up to 95%

     

    ● kVA=kW, output PF=1

     

    ● Intelligent charging management, effectively improving the life time of battery

     

    ● 3 level of technology, compatible with complicated load

     

  •   HR1101S HR1101L HR1102S HR1102L HR1103S HR1103L
    INPUT  
    Cold Start YES, default frequency=50Hz or settable
    Acceptable Input Voltage 110VAC~288VAC
      100% load@>176VAC
    80% load@>154VAC
    70% load@>132VAC
    50% load@>110VAC
    Phase Single phase in,single phase out
    Transfer Voltage Range   (200VAC/208VAC/220VAC/230VAC/240VAC)
        -Line low transfer 110VAC
        -Line low recovery 121VAC
        -Line high transfer 288VAC
        -Line high recovery 281VAC
    Input Current  
        -Rating(nominal input voltage) 4.8A 9.6A 14.4A
    Input Power Factor 0.97
    Input Connection IEC C14 IEC C20 IEC C20
    Input Frequency Range 40~70Hz
    OUTPUT      
    Frequency adaptable Settable
    Power  
        -Power(kVA) max 1 2 3
        -Power(kW) max 0.9(0.8 for 200VAC/208VAC) 1.8(1.6 for 200VAC/208VAC) 2.7(2.4 for 200VAC/208VAC)
    Output Voltage  
        -Waveform(Bat. Mode) Pure Sine Wave
        -Nominal voltage 200/208/220/230/240VAC
        -Voltage regulation ± 1 %
        -Transient response   5% (0% - 100% -0%)
        -Transient recovery 30ms (0% - 100% -0%)
        -Voltage distortion 2% THD, linear load        
      5.5% THD, non-linear load 5% THD, non-linear load 5% THD, non-linear load
    Output Frequency  
        -Synchronization range ±5Hz default
        -Battery mode (50±0.1) Hz default
    Transfer Time  
        -Line mode to battery mode 0
        -Inverter to bypass 2ms
    Efficiency  
        -Line mode with battery full charged 89%@100% load, 87%@50% load 91%@100% load, 88%@50% load 90%@100% load, 90%@50% load
        -ECO mode 94.0% 97.0% 97.0%
        -Battery mode 83%@100% load, 84%@50% load 87%@100% load, 88%@50% load 87%@100% load, 89%@50% load
    Noise(1m away) <45dB@<60%load,<50dB@>60%load <50dB@<60%load,<55dB@>60%load <50dB@<60%load,<55dB@>60%load
    Overload Capability(Inverter) 105%~130%: Transfer to bypass after 1 mins.
    150%: Transfer to bypass after 30s
    Overload Capability(Battery Mode) 105%~130%:shutdown after 10s
    150%:shutdown after 5s
    Overload Capability (Bypass Mode) <130%: Long time
    >130%&<150%:Shutdown after 10min
    >150%&<180%:Shutdown after 5 seconds
    Output Connection (6) IEC C13 (6) IEC C13 (6)IEC C13+(1)IEC C19
    Crest Ratio 3:1
    BATTERY  
    Rating/Type 12VDC/7Ah Depend on the capacity of external batteries 12VDC/7Ah Depend on the capacity of external batteries 12VDC/7Ah Depend on the capacity of external batteries
    Quantity 3 6 8
    DC Voltage 36VDC 72VDC 96VDC
    Back-up Time 6mins @80% load Depend on the capacity of external batteries 6mins @80% load Depend on the capacity of external batteries 5.5mins @80% load Depend on the capacity of external batteries
    Battery-Low Voltage 33VAC~35VDC depending on load 66VDC~70VDC depending on load 88VDC~94VDC depending on load
    Backery Maintenance Front Maintenance Online
    Charger    
        -Charging voltage float:40.5VDC/boost:41.4VDC float:81VDC/boost:82.8VDC float:108VDC/boost:110.4VDC
        -Charging current (max) 1A 8A or 4A 1A 8A or 4A 1A 8A or 4A
        -Charging time 8h recharge to 90% Depend on the capacity of external batteries 8h recharge to 90% Depend on the capacity of external batteries 8h recharge to 90% Depend on the capacity of external batteries
    Leakage current <1mA <1mA <1mA
    INDICATOR & ALARM  
        -Display LED+LCD
        -Battery discharge Sounding every 2 minutes
        -Low battery Sounding every 6 seconds
        -Overload Continuous beeping
        -Fault Continuous beeping
        -Input voltage abnormal Sounding every 2 minutes
        -Warn Sounding every 6 seconds
    INTERFACE  
        -Smart RS232 Standard Cable support INVT Power Monitor Software
        -SNMP(option) Power Managment from SNMP Manager and Web Browser
    OPTION  
        -Intelligent Kits DB9 port, dry contact
        -USB B-type USB port
        -SNMP Kits pluggable type
    MECHANICAL  
        -WDH (mm) 438*426*86(2U) 438*426*86(2U) 438*476*173(4U) 440*476*86(2U) 438*476*173(4U) 438*476*86(2U)
    max 438*437*86 438*437*86 438*488*173 440*488*86 438*488*173 438*488*86
        -WDH (mm)(shipment) 580*565*250 580*565*250 580*660*335 580*615*250 580*660*335 580*615*250
        -Net Weight (KG) 13.5 8 28 9.5 33 10.5
        -Package Weight(KG) 16 11 31 12.5 36 13.5
        -Rack / Tower Rack and Tower
    Color Black default

     

      HR1106XS HR1106XL HR1110XS HR1110XL
    INPUT  
    Cold Start YES
    Default output frequency will be 50Hz or settable
    Acceptable Input Voltage 110VAC~288VAC
      100% load@>176VAC
    90% load@>154VAC
    75% load@>132VAC
    50% load@>110VAC
    Phase Single phase in,single phase out
    Transfer Voltage Range   200VAC/208VAC/220VAC/230VAC/240VAC
        -Line low transfer 110VAC
        -Line low recovery 121VAC
        -Line high transfer 288VAC
        -Line high recovery 281VAC
    Input Current  
        -Rating(full charging) 30A/220V 34A/220V 49A/220V 53A/220V
    Input Power Factor 0.99
    Input current distortion <4%
    Input Frequency Range 40~70Hz
    OUTPUT  
    Frequency adaptable Settable
    Power  
        -Power 6KVA 10KVA
        -Power(kW)  6KW 10KW
    Output Voltage  
        -Waveform(Bat. Mode) Pure Sine Wave
        -Nominal voltage 220VAC/230VAC/240VAC,  200VAC/208VAC(PF=0.9)
        -Voltage regulation ± 1 %
        -Voltage distortion 1% THD, linear load        
    5% THD, non linear load
    Output Frequency  
        -Synchronization range ±5Hz default, settable
        -Battery mode (50±0.1) Hz default
    Transfer Time  
        -Line mode to battery mode 0ms
        -Inverter to bypass 0ms
    Efficiency  
        -Line mode with battery full charged 94.6%@100% load, 95%@60% load
        -ECO mode 98.0%
    Noise(1m away)  <58dB
    Overload Capability(Inverter) 105% to 110% : Transfer to bypass after 10 mins.
    111% to 125% : Transfer to bypass after 1 mins.
    126% to 150%: Transfer to bypass after 30s
    Overload Capability (Bypass Mode) less than 125%: long time running
     126% to 130% :Shutdown in 5 mins
     131% to 150% :Shutdown in 1 mins
    > 150%  :Shutdown in 200 ms
    Crest Ratio 3:1
    BATTERY  
    Rating/Type 12VDC/7Ah Depend on the capacity of external batteries 12VDC/9Ah Depend on the capacity of external batteries
    Quantity 16PCS  16-20PCS settable 16PCS 16-20PCS settable
    DC Voltage 192VDC default, settable
    Back-up Time 3mins @5kW Depend on the capacity of external batteries 2mins @8kW Depend on the capacity of external batteries
    Charger  
        -Charging current (max) 1A, settable 5A max,settable 1A,settable 5A max,settable
        -Float Charging Voltage 2.25V/cell default, setttable via software
        -Boost Charging Voltage 2.25V/cell default, setttable via software
        -Charging time 8h recharge to 90% Depend on the capacity of external batteries 8h recharge to 90% Depend on the capacity of external batteries
    Leakage current <3mA
    Indicator & Alarm  
        -Display LED+LCD
    Inteface  
        -Smart RS232 Standard Cable support INVT Power Monitor Software
        -EPO NC
        -RS485(option) Installed in the intelligent slot
        -SNMP(option) Power Managment from SNMP Manager and Web Browser
    Option  
        -Intelligent Kits DB9 port, dry contact
        -parallel 4 units paralleled
        -Super charger (12A) digitally controlled, 4-steps charge, settable, @PF0.9
        -USB B-type USB port
        -SNMP Kits Pluggable type
    Mechanical  
        -WDH (mm) 440*660*172 440*550*86 440*660*172 440*550*86
        -Net Weight (KG) 58 16 62 18
        -Package Weight (KG) 63 18 68 21
        -Rack / Tower Rack/Tower
    Color Black default
  • Brochure of HR11 Series Rack Online UPS 1-10kVA (220V230V240V).pdf   

Features

Specifications

Certification

Download

Common features for 1-10kVA:

 

● Wide range of input voltage while input PF>99%

 

● 19” standard cabinet and battery cabinet

 

● Full protection of overvoltage, circuit short and over temperature

 

● LCD/LED display, monitoring all the operation status

 

● Automatic fan speed adjustment

 

● Abundant interface: RS232,USB, SNMP, Intelligent Card

 

Unique features for 6-10kVA:

 

● High efficiency, up to 95%

 

● kVA=kW, output PF=1

 

● Intelligent charging management, effectively improving the life time of battery

 

● 3 level of technology, compatible with complicated load

 

  HR1101S HR1101L HR1102S HR1102L HR1103S HR1103L
INPUT  
Cold Start YES, default frequency=50Hz or settable
Acceptable Input Voltage 110VAC~288VAC
  100% load@>176VAC
80% load@>154VAC
70% load@>132VAC
50% load@>110VAC
Phase Single phase in,single phase out
Transfer Voltage Range   (200VAC/208VAC/220VAC/230VAC/240VAC)
    -Line low transfer 110VAC
    -Line low recovery 121VAC
    -Line high transfer 288VAC
    -Line high recovery 281VAC
Input Current  
    -Rating(nominal input voltage) 4.8A 9.6A 14.4A
Input Power Factor 0.97
Input Connection IEC C14 IEC C20 IEC C20
Input Frequency Range 40~70Hz
OUTPUT      
Frequency adaptable Settable
Power  
    -Power(kVA) max 1 2 3
    -Power(kW) max 0.9(0.8 for 200VAC/208VAC) 1.8(1.6 for 200VAC/208VAC) 2.7(2.4 for 200VAC/208VAC)
Output Voltage  
    -Waveform(Bat. Mode) Pure Sine Wave
    -Nominal voltage 200/208/220/230/240VAC
    -Voltage regulation ± 1 %
    -Transient response   5% (0% - 100% -0%)
    -Transient recovery 30ms (0% - 100% -0%)
    -Voltage distortion 2% THD, linear load        
  5.5% THD, non-linear load 5% THD, non-linear load 5% THD, non-linear load
Output Frequency  
    -Synchronization range ±5Hz default
    -Battery mode (50±0.1) Hz default
Transfer Time  
    -Line mode to battery mode 0
    -Inverter to bypass 2ms
Efficiency  
    -Line mode with battery full charged 89%@100% load, 87%@50% load 91%@100% load, 88%@50% load 90%@100% load, 90%@50% load
    -ECO mode 94.0% 97.0% 97.0%
    -Battery mode 83%@100% load, 84%@50% load 87%@100% load, 88%@50% load 87%@100% load, 89%@50% load
Noise(1m away) <45dB@<60%load,<50dB@>60%load <50dB@<60%load,<55dB@>60%load <50dB@<60%load,<55dB@>60%load
Overload Capability(Inverter) 105%~130%: Transfer to bypass after 1 mins.
150%: Transfer to bypass after 30s
Overload Capability(Battery Mode) 105%~130%:shutdown after 10s
150%:shutdown after 5s
Overload Capability (Bypass Mode) <130%: Long time
>130%&<150%:Shutdown after 10min
>150%&<180%:Shutdown after 5 seconds
Output Connection (6) IEC C13 (6) IEC C13 (6)IEC C13+(1)IEC C19
Crest Ratio 3:1
BATTERY  
Rating/Type 12VDC/7Ah Depend on the capacity of external batteries 12VDC/7Ah Depend on the capacity of external batteries 12VDC/7Ah Depend on the capacity of external batteries
Quantity 3 6 8
DC Voltage 36VDC 72VDC 96VDC
Back-up Time 6mins @80% load Depend on the capacity of external batteries 6mins @80% load Depend on the capacity of external batteries 5.5mins @80% load Depend on the capacity of external batteries
Battery-Low Voltage 33VAC~35VDC depending on load 66VDC~70VDC depending on load 88VDC~94VDC depending on load
Backery Maintenance Front Maintenance Online
Charger    
    -Charging voltage float:40.5VDC/boost:41.4VDC float:81VDC/boost:82.8VDC float:108VDC/boost:110.4VDC
    -Charging current (max) 1A 8A or 4A 1A 8A or 4A 1A 8A or 4A
    -Charging time 8h recharge to 90% Depend on the capacity of external batteries 8h recharge to 90% Depend on the capacity of external batteries 8h recharge to 90% Depend on the capacity of external batteries
Leakage current <1mA <1mA <1mA
INDICATOR & ALARM  
    -Display LED+LCD
    -Battery discharge Sounding every 2 minutes
    -Low battery Sounding every 6 seconds
    -Overload Continuous beeping
    -Fault Continuous beeping
    -Input voltage abnormal Sounding every 2 minutes
    -Warn Sounding every 6 seconds
INTERFACE  
    -Smart RS232 Standard Cable support INVT Power Monitor Software
    -SNMP(option) Power Managment from SNMP Manager and Web Browser
OPTION  
    -Intelligent Kits DB9 port, dry contact
    -USB B-type USB port
    -SNMP Kits pluggable type
MECHANICAL  
    -WDH (mm) 438*426*86(2U) 438*426*86(2U) 438*476*173(4U) 440*476*86(2U) 438*476*173(4U) 438*476*86(2U)
max 438*437*86 438*437*86 438*488*173 440*488*86 438*488*173 438*488*86
    -WDH (mm)(shipment) 580*565*250 580*565*250 580*660*335 580*615*250 580*660*335 580*615*250
    -Net Weight (KG) 13.5 8 28 9.5 33 10.5
    -Package Weight(KG) 16 11 31 12.5 36 13.5
    -Rack / Tower Rack and Tower
Color Black default

 

  HR1106XS HR1106XL HR1110XS HR1110XL
INPUT  
Cold Start YES
Default output frequency will be 50Hz or settable
Acceptable Input Voltage 110VAC~288VAC
  100% load@>176VAC
90% load@>154VAC
75% load@>132VAC
50% load@>110VAC
Phase Single phase in,single phase out
Transfer Voltage Range   200VAC/208VAC/220VAC/230VAC/240VAC
    -Line low transfer 110VAC
    -Line low recovery 121VAC
    -Line high transfer 288VAC
    -Line high recovery 281VAC
Input Current  
    -Rating(full charging) 30A/220V 34A/220V 49A/220V 53A/220V
Input Power Factor 0.99
Input current distortion <4%
Input Frequency Range 40~70Hz
OUTPUT  
Frequency adaptable Settable
Power  
    -Power 6KVA 10KVA
    -Power(kW)  6KW 10KW
Output Voltage  
    -Waveform(Bat. Mode) Pure Sine Wave
    -Nominal voltage 220VAC/230VAC/240VAC,  200VAC/208VAC(PF=0.9)
    -Voltage regulation ± 1 %
    -Voltage distortion 1% THD, linear load        
5% THD, non linear load
Output Frequency  
    -Synchronization range ±5Hz default, settable
    -Battery mode (50±0.1) Hz default
Transfer Time  
    -Line mode to battery mode 0ms
    -Inverter to bypass 0ms
Efficiency  
    -Line mode with battery full charged 94.6%@100% load, 95%@60% load
    -ECO mode 98.0%
Noise(1m away)  <58dB
Overload Capability(Inverter) 105% to 110% : Transfer to bypass after 10 mins.
111% to 125% : Transfer to bypass after 1 mins.
126% to 150%: Transfer to bypass after 30s
Overload Capability (Bypass Mode) less than 125%: long time running
 126% to 130% :Shutdown in 5 mins
 131% to 150% :Shutdown in 1 mins
> 150%  :Shutdown in 200 ms
Crest Ratio 3:1
BATTERY  
Rating/Type 12VDC/7Ah Depend on the capacity of external batteries 12VDC/9Ah Depend on the capacity of external batteries
Quantity 16PCS  16-20PCS settable 16PCS 16-20PCS settable
DC Voltage 192VDC default, settable
Back-up Time 3mins @5kW Depend on the capacity of external batteries 2mins @8kW Depend on the capacity of external batteries
Charger  
    -Charging current (max) 1A, settable 5A max,settable 1A,settable 5A max,settable
    -Float Charging Voltage 2.25V/cell default, setttable via software
    -Boost Charging Voltage 2.25V/cell default, setttable via software
    -Charging time 8h recharge to 90% Depend on the capacity of external batteries 8h recharge to 90% Depend on the capacity of external batteries
Leakage current <3mA
Indicator & Alarm  
    -Display LED+LCD
Inteface  
    -Smart RS232 Standard Cable support INVT Power Monitor Software
    -EPO NC
    -RS485(option) Installed in the intelligent slot
    -SNMP(option) Power Managment from SNMP Manager and Web Browser
Option  
    -Intelligent Kits DB9 port, dry contact
    -parallel 4 units paralleled
    -Super charger (12A) digitally controlled, 4-steps charge, settable, @PF0.9
    -USB B-type USB port
    -SNMP Kits Pluggable type
Mechanical  
    -WDH (mm) 440*660*172 440*550*86 440*660*172 440*550*86
    -Net Weight (KG) 58 16 62 18
    -Package Weight (KG) 63 18 68 21
    -Rack / Tower Rack/Tower
Color Black default

Related Application Cases

Related Products

HR31 Series Rack Online UPS 15-20kVA (220V/230V/240V)

The series 3:1 Rack Online UPS is online double-conversion UPS with full DSP control technology. With high input and output power factor, self-adjusting output frequency and network management. The series has 15kVA, 20kVA can be chosen.

HTC11 Series Tower Online UPS 1-3kVA 2.0 (220V/230V/240V)

This series tower UPS is the 2.0 version of HT11 1-3kVA, which is to meet the requirements for energy conservation and emission reduction of the markets, compared with the old one, it has a smaller size, better performance, and more competitive price and quality! its power ranges from 1kVA to 3kVA, This product can be widely used, such as small data centers, bank branches, telecom business halls, office buildings, and various edge computing scenarios.

HT11 Series Tower Online UPS 6-20kVA (220V/230V/240V)

This series tower online UPS contain a standard model with built-in batteries and a long backup model.Smaller size with higher power density, double conversion online UPS with fully DSP controlled technology,this series is a perfect choice for computers, telecommunication equipment and other sensitive devices. The series has 6kVA, 10kVA, 15kVA, 20kVA can be chosen.

HT31 Series Tower Online UPS 10-40kVA (220V/230V/240V)

The series 3:1 Tower Online UPS is double conversion online UPS with fully DSP controlled technology. it provides 12A charger for option, and the digital charger can adjust from 1A to 5A. It’s a perfect choice for computers, telecommunication equipments and other sensitive devices. The series has 10kVA, 15kVA, 20kVA, 40kVA can be chosen.