HR11 Series Rack Online UPS 1-10kVA (220V/230V/240V)
The series 1:1 Rack Online UPS is the ideal choice for small data center. It supports in-built battery. And the 6kVA and 10kVA rack UPS of this series apply the advanced 3 level of technology, compatible with complicated load. The series has 1kVA, 2kVA, 3kVA, 6kVA, 10 kVA can be chosen. ( watch the introduction video on YouTube)
Email Us
- Product description
- Features
- Specifications
- Certification
- Download
-
The series 1:1 Rack Online UPS is the ideal choice for small data center. It supports in-built battery. And the 6kVA and 10kVA rack UPS of this series apply the advanced 3 level of technology, compatible with complicated load. The series has 1kVA, 2kVA, 3kVA, 6kVA, 10 kVA can be chosen. ( watch the introduction video on YouTube)
-
Common features for 1-10kVA:
● Wide range of input voltage while input PF>99%
● 19” standard cabinet and battery cabinet
● Full protection of overvoltage, circuit short and over temperature
● LCD/LED display, monitoring all the operation status
● Automatic fan speed adjustment
● Abundant interface: RS232,USB, SNMP, Intelligent Card
Unique features for 6-10kVA:
● High efficiency, up to 95%
● kVA=kW, output PF=1
● Intelligent charging management, effectively improving the life time of battery
● 3 level of technology, compatible with complicated load
-
HR1101S HR1101L HR1102S HR1102L HR1103S HR1103L INPUT Cold Start YES, default frequency=50Hz or settable Acceptable Input Voltage 110VAC~288VAC 100% load@>176VAC 80% load@>154VAC 70% load@>132VAC 50% load@>110VAC Phase Single phase in,single phase out Transfer Voltage Range (200VAC/208VAC/220VAC/230VAC/240VAC) -Line low transfer 110VAC -Line low recovery 121VAC -Line high transfer 288VAC -Line high recovery 281VAC Input Current -Rating(nominal input voltage) 4.8A 9.6A 14.4A Input Power Factor ≥0.97 Input Connection IEC C14 IEC C20 IEC C20 Input Frequency Range 40~70Hz OUTPUT Frequency adaptable Settable Power -Power(kVA) max 1 2 3 -Power(kW) max 0.9(0.8 for 200VAC/208VAC) 1.8(1.6 for 200VAC/208VAC) 2.7(2.4 for 200VAC/208VAC) Output Voltage -Waveform(Bat. Mode) Pure Sine Wave -Nominal voltage 200/208/220/230/240VAC -Voltage regulation ± 1 % -Transient response ≤5% (0% - 100% -0%) -Transient recovery ≤30ms (0% - 100% -0%) -Voltage distortion ≤2% THD, linear load ≤ 5.5% THD, non-linear load ≤ 5% THD, non-linear load ≤ 5% THD, non-linear load Output Frequency -Synchronization range ±5Hz default -Battery mode (50±0.1) Hz default Transfer Time -Line mode to battery mode 0 -Inverter to bypass 2ms Efficiency -Line mode with battery full charged 89%@100% load, 87%@50% load 91%@100% load, 88%@50% load 90%@100% load, 90%@50% load -ECO mode 94.0% 97.0% 97.0% -Battery mode 83%@100% load, 84%@50% load 87%@100% load, 88%@50% load 87%@100% load, 89%@50% load Noise(1m away) <45dB@<60%load,<50dB@>60%load <50dB@<60%load,<55dB@>60%load <50dB@<60%load,<55dB@>60%load Overload Capability(Inverter) 105%~130%: Transfer to bypass after 1 mins. 150%: Transfer to bypass after 30s Overload Capability(Battery Mode) 105%~130%:shutdown after 10s 150%:shutdown after 5s Overload Capability (Bypass Mode) <130%: Long time >130%&<150%:Shutdown after 10min >150%&<180%:Shutdown after 5 seconds Output Connection (6) IEC C13 (6) IEC C13 (6)IEC C13+(1)IEC C19 Crest Ratio 3:1 BATTERY Rating/Type 12VDC/7Ah Depend on the capacity of external batteries 12VDC/7Ah Depend on the capacity of external batteries 12VDC/7Ah Depend on the capacity of external batteries Quantity 3 6 8 DC Voltage 36VDC 72VDC 96VDC Back-up Time 6mins @80% load Depend on the capacity of external batteries 6mins @80% load Depend on the capacity of external batteries 5.5mins @80% load Depend on the capacity of external batteries Battery-Low Voltage 33VAC~35VDC depending on load 66VDC~70VDC depending on load 88VDC~94VDC depending on load Backery Maintenance Front Maintenance Online Charger -Charging voltage float:40.5VDC/boost:41.4VDC float:81VDC/boost:82.8VDC float:108VDC/boost:110.4VDC -Charging current (max) 1A 8A or 4A 1A 8A or 4A 1A 8A or 4A -Charging time 8h recharge to 90% Depend on the capacity of external batteries 8h recharge to 90% Depend on the capacity of external batteries 8h recharge to 90% Depend on the capacity of external batteries Leakage current <1mA <1mA <1mA INDICATOR & ALARM -Display LED+LCD -Battery discharge Sounding every 2 minutes -Low battery Sounding every 6 seconds -Overload Continuous beeping -Fault Continuous beeping -Input voltage abnormal Sounding every 2 minutes -Warn Sounding every 6 seconds INTERFACE -Smart RS232 Standard Cable support INVT Power Monitor Software -SNMP(option) Power Managment from SNMP Manager and Web Browser OPTION -Intelligent Kits DB9 port, dry contact -USB B-type USB port -SNMP Kits pluggable type MECHANICAL -W╳D╳H (mm) 438*426*86(2U) 438*426*86(2U) 438*476*173(4U) 440*476*86(2U) 438*476*173(4U) 438*476*86(2U) (max) 438*437*86 438*437*86 438*488*173 440*488*86 438*488*173 438*488*86 -W╳D╳H (mm)(shipment) 580*565*250 580*565*250 580*660*335 580*615*250 580*660*335 580*615*250 -Net Weight (KG) 13.5 8 28 9.5 33 10.5 -Package Weight(KG) 16 11 31 12.5 36 13.5 -Rack / Tower Rack and Tower Color Black default HR1106XS HR1106XL HR1110XS HR1110XL INPUT Cold Start YES
Default output frequency will be 50Hz or settableAcceptable Input Voltage 110VAC~288VAC 100% load@>176VAC 90% load@>154VAC 75% load@>132VAC 50% load@>110VAC Phase Single phase in,single phase out Transfer Voltage Range 200VAC/208VAC/220VAC/230VAC/240VAC -Line low transfer 110VAC -Line low recovery 121VAC -Line high transfer 288VAC -Line high recovery 281VAC Input Current -Rating(full charging) 30A/220V 34A/220V 49A/220V 53A/220V Input Power Factor ≥0.99 Input current distortion <4% Input Frequency Range 40~70Hz OUTPUT Frequency adaptable Settable Power -Power 6KVA 10KVA -Power(kW) 6KW 10KW Output Voltage -Waveform(Bat. Mode) Pure Sine Wave -Nominal voltage 220VAC/230VAC/240VAC, 200VAC/208VAC(PF=0.9) -Voltage regulation ± 1 % -Voltage distortion ≤1% THD, linear load ≤ 5% THD, non linear load Output Frequency -Synchronization range ±5Hz default, settable -Battery mode (50±0.1) Hz default Transfer Time -Line mode to battery mode 0ms -Inverter to bypass 0ms Efficiency -Line mode with battery full charged 94.6%@100% load, 95%@60% load -ECO mode 98.0% Noise(1m away) <58dB Overload Capability(Inverter) 105% to 110% : Transfer to bypass after 10 mins. 111% to 125% : Transfer to bypass after 1 mins. 126% to 150%: Transfer to bypass after 30s Overload Capability (Bypass Mode) less than 125%: long time running 126% to 130% :Shutdown in 5 mins 131% to 150% :Shutdown in 1 mins > 150% :Shutdown in 200 ms Crest Ratio 3:1 BATTERY Rating/Type 12VDC/7Ah Depend on the capacity of external batteries 12VDC/9Ah Depend on the capacity of external batteries Quantity 16PCS 16-20PCS settable 16PCS 16-20PCS settable DC Voltage 192VDC default, settable Back-up Time 3mins @5kW Depend on the capacity of external batteries 2mins @8kW Depend on the capacity of external batteries Charger -Charging current (max) 1A, settable 5A max,settable 1A,settable 5A max,settable -Float Charging Voltage 2.25V/cell default, setttable via software -Boost Charging Voltage 2.25V/cell default, setttable via software -Charging time 8h recharge to 90% Depend on the capacity of external batteries 8h recharge to 90% Depend on the capacity of external batteries Leakage current <3mA Indicator & Alarm -Display LED+LCD Inteface -Smart RS232 Standard Cable support INVT Power Monitor Software -EPO NC -RS485(option) Installed in the intelligent slot -SNMP(option) Power Managment from SNMP Manager and Web Browser Option -Intelligent Kits DB9 port, dry contact -parallel 4 units paralleled -Super charger (12A) digitally controlled, 4-steps charge, settable, @PF0.9 -USB B-type USB port -SNMP Kits Pluggable type Mechanical -W╳D╳H (mm) 440*660*172 440*550*86 440*660*172 440*550*86 -Net Weight (KG) 58 16 62 18 -Package Weight (KG) 63 18 68 21 -Rack / Tower Rack/Tower Color Black default -
Brochure of HR11 Series Rack Online UPS 1-10kVA (220V230V240V).pdf
Features
Specifications
Certification
Download
Common features for 1-10kVA:
● Wide range of input voltage while input PF>99%
● 19” standard cabinet and battery cabinet
● Full protection of overvoltage, circuit short and over temperature
● LCD/LED display, monitoring all the operation status
● Automatic fan speed adjustment
● Abundant interface: RS232,USB, SNMP, Intelligent Card
Unique features for 6-10kVA:
● High efficiency, up to 95%
● kVA=kW, output PF=1
● Intelligent charging management, effectively improving the life time of battery
● 3 level of technology, compatible with complicated load
HR1101S | HR1101L | HR1102S | HR1102L | HR1103S | HR1103L | |
INPUT | ||||||
Cold Start | YES, default frequency=50Hz or settable | |||||
Acceptable Input Voltage | 110VAC~288VAC | |||||
100% load@>176VAC | ||||||
80% load@>154VAC | ||||||
70% load@>132VAC | ||||||
50% load@>110VAC | ||||||
Phase | Single phase in,single phase out | |||||
Transfer Voltage Range | (200VAC/208VAC/220VAC/230VAC/240VAC) | |||||
-Line low transfer | 110VAC | |||||
-Line low recovery | 121VAC | |||||
-Line high transfer | 288VAC | |||||
-Line high recovery | 281VAC | |||||
Input Current | ||||||
-Rating(nominal input voltage) | 4.8A | 9.6A | 14.4A | |||
Input Power Factor | ≥0.97 | |||||
Input Connection | IEC C14 | IEC C20 | IEC C20 | |||
Input Frequency Range | 40~70Hz | |||||
OUTPUT | ||||||
Frequency adaptable | Settable | |||||
Power | ||||||
-Power(kVA) max | 1 | 2 | 3 | |||
-Power(kW) max | 0.9(0.8 for 200VAC/208VAC) | 1.8(1.6 for 200VAC/208VAC) | 2.7(2.4 for 200VAC/208VAC) | |||
Output Voltage | ||||||
-Waveform(Bat. Mode) | Pure Sine Wave | |||||
-Nominal voltage | 200/208/220/230/240VAC | |||||
-Voltage regulation | ± 1 % | |||||
-Transient response | ≤5% (0% - 100% -0%) | |||||
-Transient recovery | ≤30ms (0% - 100% -0%) | |||||
-Voltage distortion | ≤2% THD, linear load | |||||
≤ 5.5% THD, non-linear load | ≤ 5% THD, non-linear load | ≤ 5% THD, non-linear load | ||||
Output Frequency | ||||||
-Synchronization range | ±5Hz default | |||||
-Battery mode | (50±0.1) Hz default | |||||
Transfer Time | ||||||
-Line mode to battery mode | 0 | |||||
-Inverter to bypass | 2ms | |||||
Efficiency | ||||||
-Line mode with battery full charged | 89%@100% load, 87%@50% load | 91%@100% load, 88%@50% load | 90%@100% load, 90%@50% load | |||
-ECO mode | 94.0% | 97.0% | 97.0% | |||
-Battery mode | 83%@100% load, 84%@50% load | 87%@100% load, 88%@50% load | 87%@100% load, 89%@50% load | |||
Noise(1m away) | <45dB@<60%load,<50dB@>60%load | <50dB@<60%load,<55dB@>60%load | <50dB@<60%load,<55dB@>60%load | |||
Overload Capability(Inverter) | 105%~130%: Transfer to bypass after 1 mins. | |||||
150%: Transfer to bypass after 30s | ||||||
Overload Capability(Battery Mode) | 105%~130%:shutdown after 10s | |||||
150%:shutdown after 5s | ||||||
Overload Capability (Bypass Mode) | <130%: Long time | |||||
>130%&<150%:Shutdown after 10min | ||||||
>150%&<180%:Shutdown after 5 seconds | ||||||
Output Connection | (6) IEC C13 | (6) IEC C13 | (6)IEC C13+(1)IEC C19 | |||
Crest Ratio | 3:1 | |||||
BATTERY | ||||||
Rating/Type | 12VDC/7Ah | Depend on the capacity of external batteries | 12VDC/7Ah | Depend on the capacity of external batteries | 12VDC/7Ah | Depend on the capacity of external batteries |
Quantity | 3 | 6 | 8 | |||
DC Voltage | 36VDC | 72VDC | 96VDC | |||
Back-up Time | 6mins @80% load | Depend on the capacity of external batteries | 6mins @80% load | Depend on the capacity of external batteries | 5.5mins @80% load | Depend on the capacity of external batteries |
Battery-Low Voltage | 33VAC~35VDC depending on load | 66VDC~70VDC depending on load | 88VDC~94VDC depending on load | |||
Backery Maintenance | Front Maintenance Online | |||||
Charger | ||||||
-Charging voltage | float:40.5VDC/boost:41.4VDC | float:81VDC/boost:82.8VDC | float:108VDC/boost:110.4VDC | |||
-Charging current (max) | 1A | 8A or 4A | 1A | 8A or 4A | 1A | 8A or 4A |
-Charging time | 8h recharge to 90% | Depend on the capacity of external batteries | 8h recharge to 90% | Depend on the capacity of external batteries | 8h recharge to 90% | Depend on the capacity of external batteries |
Leakage current | <1mA | <1mA | <1mA | |||
INDICATOR & ALARM | ||||||
-Display | LED+LCD | |||||
-Battery discharge | Sounding every 2 minutes | |||||
-Low battery | Sounding every 6 seconds | |||||
-Overload | Continuous beeping | |||||
-Fault | Continuous beeping | |||||
-Input voltage abnormal | Sounding every 2 minutes | |||||
-Warn | Sounding every 6 seconds | |||||
INTERFACE | ||||||
-Smart RS232 | Standard Cable support INVT Power Monitor Software | |||||
-SNMP(option) | Power Managment from SNMP Manager and Web Browser | |||||
OPTION | ||||||
-Intelligent Kits | DB9 port, dry contact | |||||
-USB | B-type USB port | |||||
-SNMP Kits | pluggable type | |||||
MECHANICAL | ||||||
-W╳D╳H (mm) | 438*426*86(2U) | 438*426*86(2U) | 438*476*173(4U) | 440*476*86(2U) | 438*476*173(4U) | 438*476*86(2U) |
(max) | 438*437*86 | 438*437*86 | 438*488*173 | 440*488*86 | 438*488*173 | 438*488*86 |
-W╳D╳H (mm)(shipment) | 580*565*250 | 580*565*250 | 580*660*335 | 580*615*250 | 580*660*335 | 580*615*250 |
-Net Weight (KG) | 13.5 | 8 | 28 | 9.5 | 33 | 10.5 |
-Package Weight(KG) | 16 | 11 | 31 | 12.5 | 36 | 13.5 |
-Rack / Tower | Rack and Tower | |||||
Color | Black default |
HR1106XS | HR1106XL | HR1110XS | HR1110XL | |
INPUT | ||||
Cold Start | YES Default output frequency will be 50Hz or settable |
|||
Acceptable Input Voltage | 110VAC~288VAC | |||
100% load@>176VAC | ||||
90% load@>154VAC | ||||
75% load@>132VAC | ||||
50% load@>110VAC | ||||
Phase | Single phase in,single phase out | |||
Transfer Voltage Range | 200VAC/208VAC/220VAC/230VAC/240VAC | |||
-Line low transfer | 110VAC | |||
-Line low recovery | 121VAC | |||
-Line high transfer | 288VAC | |||
-Line high recovery | 281VAC | |||
Input Current | ||||
-Rating(full charging) | 30A/220V | 34A/220V | 49A/220V | 53A/220V |
Input Power Factor | ≥0.99 | |||
Input current distortion | <4% | |||
Input Frequency Range | 40~70Hz | |||
OUTPUT | ||||
Frequency adaptable | Settable | |||
Power | ||||
-Power | 6KVA | 10KVA | ||
-Power(kW) | 6KW | 10KW | ||
Output Voltage | ||||
-Waveform(Bat. Mode) | Pure Sine Wave | |||
-Nominal voltage | 220VAC/230VAC/240VAC, 200VAC/208VAC(PF=0.9) | |||
-Voltage regulation | ± 1 % | |||
-Voltage distortion | ≤1% THD, linear load | |||
≤ 5% THD, non linear load | ||||
Output Frequency | ||||
-Synchronization range | ±5Hz default, settable | |||
-Battery mode | (50±0.1) Hz default | |||
Transfer Time | ||||
-Line mode to battery mode | 0ms | |||
-Inverter to bypass | 0ms | |||
Efficiency | ||||
-Line mode with battery full charged | 94.6%@100% load, 95%@60% load | |||
-ECO mode | 98.0% | |||
Noise(1m away) | <58dB | |||
Overload Capability(Inverter) | 105% to 110% : Transfer to bypass after 10 mins. | |||
111% to 125% : Transfer to bypass after 1 mins. | ||||
126% to 150%: Transfer to bypass after 30s | ||||
Overload Capability (Bypass Mode) | less than 125%: long time running | |||
126% to 130% :Shutdown in 5 mins | ||||
131% to 150% :Shutdown in 1 mins | ||||
> 150% :Shutdown in 200 ms | ||||
Crest Ratio | 3:1 | |||
BATTERY | ||||
Rating/Type | 12VDC/7Ah | Depend on the capacity of external batteries | 12VDC/9Ah | Depend on the capacity of external batteries |
Quantity | 16PCS | 16-20PCS settable | 16PCS | 16-20PCS settable |
DC Voltage | 192VDC default, settable | |||
Back-up Time | 3mins @5kW | Depend on the capacity of external batteries | 2mins @8kW | Depend on the capacity of external batteries |
Charger | ||||
-Charging current (max) | 1A, settable | 5A max,settable | 1A,settable | 5A max,settable |
-Float Charging Voltage | 2.25V/cell default, setttable via software | |||
-Boost Charging Voltage | 2.25V/cell default, setttable via software | |||
-Charging time | 8h recharge to 90% | Depend on the capacity of external batteries | 8h recharge to 90% | Depend on the capacity of external batteries |
Leakage current | <3mA | |||
Indicator & Alarm | ||||
-Display | LED+LCD | |||
Inteface | ||||
-Smart RS232 | Standard Cable support INVT Power Monitor Software | |||
-EPO | NC | |||
-RS485(option) | Installed in the intelligent slot | |||
-SNMP(option) | Power Managment from SNMP Manager and Web Browser | |||
Option | ||||
-Intelligent Kits | DB9 port, dry contact | |||
-parallel | 4 units paralleled | |||
-Super charger (12A) | digitally controlled, 4-steps charge, settable, @PF0.9 | |||
-USB | B-type USB port | |||
-SNMP Kits | Pluggable type | |||
Mechanical | ||||
-W╳D╳H (mm) | 440*660*172 | 440*550*86 | 440*660*172 | 440*550*86 |
-Net Weight (KG) | 58 | 16 | 62 | 18 |
-Package Weight (KG) | 63 | 18 | 68 | 21 |
-Rack / Tower | Rack/Tower | |||
Color | Black default |
Related Application Cases
Related Products
HR31 Series Rack Online UPS 15-20kVA (220V/230V/240V)
The series 3:1 Rack Online UPS is online double-conversion UPS with full DSP control technology. With high input and output power factor, self-adjusting output frequency and network management. The series has 15kVA, 20kVA can be chosen.
HTC11 Series Tower Online UPS 1-3kVA 2.0 (220V/230V/240V)
This series tower UPS is the 2.0 version of HT11 1-3kVA, which is to meet the requirements for energy conservation and emission reduction of the markets, compared with the old one, it has a smaller size, better performance, and more competitive price and quality! its power ranges from 1kVA to 3kVA, This product can be widely used, such as small data centers, bank branches, telecom business halls, office buildings, and various edge computing scenarios.
HT11 Series Tower Online UPS 6-20kVA (220V/230V/240V)
This series tower online UPS contain a standard model with built-in batteries and a long backup model.Smaller size with higher power density, double conversion online UPS with fully DSP controlled technology,this series is a perfect choice for computers, telecommunication equipment and other sensitive devices. The series has 6kVA, 10kVA, 15kVA, 20kVA can be chosen.
HT31 Series Tower Online UPS 10-40kVA (220V/230V/240V)
The series 3:1 Tower Online UPS is double conversion online UPS with fully DSP controlled technology. it provides 12A charger for option, and the digital charger can adjust from 1A to 5A. It’s a perfect choice for computers, telecommunication equipments and other sensitive devices. The series has 10kVA, 15kVA, 20kVA, 40kVA can be chosen.