HT33 Series Tower Online UPS 60-500kVA (380V/400V/415V)

The series Tower Online UPS is a high stability and scalability product for medium and large data center. The series has 60kVA, 80kVA, 90kVA, 100kVA, 120kVA, 150kVA, 200kVA, 250kVA, 300kVA, 400kVA, 500kVA can be chosen. And it supports swappable, each power module capacity reaches 500kVA in one cabinet but footprint less than 1.45m2. ( watch the introduction video on YouTube )


Email Us
  • Product description
  • Features
  • Specifications
  • Certification
  • Download
    • Commodity name: HT33 Series Tower Online UPS 60-500kVA (380V/400V/415V)
    • Commodity ID: 1063519152443641856

    The series Tower Online UPS is a high stability and scalability product for medium and large data center. The series has 60kVA, 80kVA, 90kVA, 100kVA, 120kVA, 150kVA, 200kVA, 250kVA, 300kVA, 400kVA, 500kVA can be chosen. And it supports swappable, each power module capacity reaches 500kVA in one cabinet but footprint less than 1.45m2.

    The series Tower Online UPS is a high stability and scalability product for medium and large data center. The series has 60kVA, 80kVA, 90kVA, 100kVA, 120kVA, 150kVA, 200kVA, 250kVA, 300kVA, 400kVA, 500kVA can be chosen. And it supports swappable, each power module capacity reaches 500kVA in one cabinet but footprint less than 1.45m2. ( watch the introduction video on YouTube )

  • ● High Efficiency, up to 96%

     

    ● High input PF>0.99; Input current THDi<3%

     

    ● Muti-protection, as temperature, overload, battery under voltage, fan failures, short-circuit

     

    ● Battery cold start

     

    ● Battery management: smart charging control, auto maintenance, greatly extend the battery life

     

    ● High power density

     

    ● Parallel up to 1500kVA

     

    ● Modular design of subsystem, convenient for field maintenance

     

    ● Friendly Operation Interface, touch LCD Screen

     

  •   Model HT33060X HT33080X HT33090X HT33100X HT33120X HT33150X HT33200X HT33250X HT33300X HT33400X HT33500X
      System Capacity 60kVA 80kVA 90kVA 100kVA 120kVA 150kVA 200kVA 250kVA 300kVA 400KVA 500KVA
    Input Dual Input Standard Optional Standard
    Phase 3 Phase+Neutral+Ground, 380V/400V/415V(line-line)
    Input Voltage Range 304~478Vac (Line-Line),full load
    228V~304Vac (Line-Line),load decrease linearly according to the min phase voltage 
    Rated Frequency 50/60Hz
    Input Frequency Range 40Hz~70Hz
    Input PF >0.99 
    Input THDi <3% (100% Linear load)
    Bypass Rate Voltage 380/400/415Vac (Line-Line)
    Rate Frequency 50/60Hz
    Input Voltage Range Settable, -40%~+25%
    Bypass Frequency Range Settable, ±1Hz, ±3Hz, ±5Hz
    Bypass Overload 125% long term operation
    130% for 10 mins
    150% for 1 min
    >150% for 300ms
    110% long term operation
    125 % for 5 mins
    150% for 1 min
    >150% for 1s
    Output Rate Voltage 380/400/415Vac (Line-Line)
    Voltage Regulation  1% for balance load; 1.5% for unbalance load
    Rate Frequency 50/60Hz
    Voltage Precision 0.1%
    Output PF 1
    Output THDu  <1% , Linear load; <5.5%, Non-linear load
    Crest Factor  3:1
    Inverter Overload  110% for 1 hour; 125% for 10 mins ;150% for 1 min; >150% for 200 ms
    Battery Voltage ±240Vdc
    Battery Number 40pcs (Settable: even number from 32 to 44)
    Voltage Precision ±1%
    Charge Power up to 20% * Output active power
    Battery Cold Start  Optional Standard
    System Efficiency AC Mode   95%  96%  95%  96%  95%  96%
    ECO Mode   99%
    Battery Mode  95%  96%  95%  96%  95%  96%
    Display  10.4"(240kVA-500kVA) or 7''(60kVA-200kVA) touch screen LCD + LED + keyboard
    IP Class IP 20
    Interface RS232,RS485, Programmable Dry Contact, USB
    Option SNMP Card, Parallel kit, SPD, LBS, Dust filter
    Temperature Operation: -40~70 ℃
    Relative Humidity  0~95% Non-condensing
    Altitude  <1000m. Within 1000m to 2000m, 1% power derating for every 100m rise
    Noise (1 meter) 65dB @ 100% load, 62dB @ 45% load
    Applicable Standards  Safety: IEC/EN 62040-1  EMC: IEC/EN 62040-2  Performance: IEC/EN 62040-3 
    Physical Weigh (kg) 170 210 231 210 266 305 350 445 490 700 900
    Dimension W*D*H (mm) 600*980
     *950
    600*980
     *1150
    600*980
     *1400
    600*980
     *1150
    600*980
     *1400
    650*960
     *1600
    650*960
     *1600
    650*970
     *2000
    650*970
     *2000
    1050*1000
     *2000
    1300*1000
     *2000

Features

Specifications

Certification

Download

● High Efficiency, up to 96%

 

● High input PF>0.99; Input current THDi<3%

 

● Muti-protection, as temperature, overload, battery under voltage, fan failures, short-circuit

 

● Battery cold start

 

● Battery management: smart charging control, auto maintenance, greatly extend the battery life

 

● High power density

 

● Parallel up to 1500kVA

 

● Modular design of subsystem, convenient for field maintenance

 

● Friendly Operation Interface, touch LCD Screen

 

  Model HT33060X HT33080X HT33090X HT33100X HT33120X HT33150X HT33200X HT33250X HT33300X HT33400X HT33500X
  System Capacity 60kVA 80kVA 90kVA 100kVA 120kVA 150kVA 200kVA 250kVA 300kVA 400KVA 500KVA
Input Dual Input Standard Optional Standard
Phase 3 Phase+Neutral+Ground, 380V/400V/415V(line-line)
Input Voltage Range 304~478Vac (Line-Line),full load
228V~304Vac (Line-Line),load decrease linearly according to the min phase voltage 
Rated Frequency 50/60Hz
Input Frequency Range 40Hz~70Hz
Input PF >0.99 
Input THDi <3% (100% Linear load)
Bypass Rate Voltage 380/400/415Vac (Line-Line)
Rate Frequency 50/60Hz
Input Voltage Range Settable, -40%~+25%
Bypass Frequency Range Settable, ±1Hz, ±3Hz, ±5Hz
Bypass Overload 125% long term operation
130% for 10 mins
150% for 1 min
>150% for 300ms
110% long term operation
125 % for 5 mins
150% for 1 min
>150% for 1s
Output Rate Voltage 380/400/415Vac (Line-Line)
Voltage Regulation  1% for balance load; 1.5% for unbalance load
Rate Frequency 50/60Hz
Voltage Precision 0.1%
Output PF 1
Output THDu  <1% , Linear load; <5.5%, Non-linear load
Crest Factor  3:1
Inverter Overload  110% for 1 hour; 125% for 10 mins ;150% for 1 min; >150% for 200 ms
Battery Voltage ±240Vdc
Battery Number 40pcs (Settable: even number from 32 to 44)
Voltage Precision ±1%
Charge Power up to 20% * Output active power
Battery Cold Start  Optional Standard
System Efficiency AC Mode   95%  96%  95%  96%  95%  96%
ECO Mode   99%
Battery Mode  95%  96%  95%  96%  95%  96%
Display  10.4"(240kVA-500kVA) or 7''(60kVA-200kVA) touch screen LCD + LED + keyboard
IP Class IP 20
Interface RS232,RS485, Programmable Dry Contact, USB
Option SNMP Card, Parallel kit, SPD, LBS, Dust filter
Temperature Operation: -40~70 ℃
Relative Humidity  0~95% Non-condensing
Altitude  <1000m. Within 1000m to 2000m, 1% power derating for every 100m rise
Noise (1 meter) 65dB @ 100% load, 62dB @ 45% load
Applicable Standards  Safety: IEC/EN 62040-1  EMC: IEC/EN 62040-2  Performance: IEC/EN 62040-3 
Physical Weigh (kg) 170 210 231 210 266 305 350 445 490 700 900
Dimension W*D*H (mm) 600*980
 *950
600*980
 *1150
600*980
 *1400
600*980
 *1150
600*980
 *1400
650*960
 *1600
650*960
 *1600
650*970
 *2000
650*970
 *2000
1050*1000
 *2000
1300*1000
 *2000

Related Application Cases

Related Products

HR33 Series Rack Online UPS 30-40kVA (380V/400V/415V)

The HR33 Series Rack-mounted Online UPS adopts online double conversion design, based on DSP full digital control, to provide a stable and uninterrupted power supply for important loads, which can eliminate surges, instantaneous high voltage, instantaneous low voltage, and "Power pollution" such as wire noise and frequency offset, provide customers with high-efficiency and high-power-density power supply guarantees. the UPS can be plugged into the 19-inch standard server cabinet of the micro-module data center. The single cabinet has a capacity of 40kVA/40kW, and the system supports 4 parallel.

HT33 Series Tower Online UPS 10-40kVA (380V/400V/415V)

The series Tower Online UPS for small load scenarios, and widely used in office, health care equipment and the mall. It has 10kVA, 15kVA, 20kVA, 30kVA, 40kVA can be chosen, and supports 8 units parallel. Otherwise, the 20kVA and 30kVA product can also be used in industrial site, such as ceramic factories, glass factories and other processing industries. 

HT33-TX Series Tower Online UPS 10-40kVA (380V/400V/415V)

The series in-built transformers Tower Online UPS for small load scenarios, and widely used in office, health care equipment and the mall. It has 10kVA, 20kVA, 30kVA, 40kVA can be chosen, It has the same outstanding performance as 10-40kVA Tower Online UPS. the 20kVA and 30kVA product can also be used in industrial site, such as ceramic factories, glass factories and other processing industries. And becasue of the in-built galvanic isolation transformer, it provides more safety for small load scenarios.

HR33 Series Rack Online UPS 10-25 kVA (380V/400V/415V)

The series Rack Online UPS is the ideal choice for modern data center. It has 10kVA, 15kVA, 20kVA, 25kVA can be chosen, The series is double conversion online UPS with fully DSP controlled technology,and it can be configured with 3:3 and 3:1 flexibly.