HT31 Series Tower Online UPS 10-40kVA (220V/230V/240V)

The series 3:1 Tower Online UPS  is double conversion online UPS with fully DSP controlled technology. it provides 12A charger for option, and the digital charger can adjust from 1A to 5A. It’s a perfect choice for computers, telecommunication equipments and other sensitive devices. The series has 10kVA, 15kVA, 20kVA, 40kVA can be chosen. ( watch the introduction video on YouTube )


Email Us
  • Product description
  • Features
  • Specifications
  • Certification
  • Download
    • Commodity name: HT31 Series Tower Online UPS 10-40kVA (220V/230V/240V)
    • Commodity ID: 1063517153245417472

    The series 3:1 Tower Online UPS is double conversion online UPS with fully DSP controlled technology. it provides 12A charger for option, and the digital charger can adjust from 1A to 5A. It’s a perfect choice for computers, telecommunication equipments and other sensitive devices. The series has 10kVA, 15kVA, 20kVA, 40kVA can be chosen.

    The series 3:1 Tower Online UPS  is double conversion online UPS with fully DSP controlled technology. it provides 12A charger for option, and the digital charger can adjust from 1A to 5A. It’s a perfect choice for computers, telecommunication equipments and other sensitive devices. The series has 10kVA, 15kVA, 20kVA, 40kVA can be chosen. ( watch the introduction video on YouTube )

  • Common features:

     

    ● Full protection of overvoltage, circuit short and over temperature

     

    ● Auto fan speed adjustment

     

    ● Abundant interface:RS232, USB, SNMP, Intelligent Card

     

    ● Parallel up to 4 units

     

    Unique features:

     

    ● Output PF=1

     

    ● Small size with higher power density

     

    ● Digital Charger, adjustable from 1A to 5A

     

    ● 12A charger for option, charging for large capacity batteries

     

  •  HT3110XLHT3115XLHT3120XL HT3140L
    INPUT INPUT 
    Cold StartYES
    Default output frequency will be 50Hz or settable
      
    Acceptable Input VoltageL-L 190VAC~499VACAcceptable Input VoltageL-L 190VAC~499VAC
     100% load@>305VAC 100% load@>305VAC
    90% load@>266VAC90% load@>266VAC
    75% load@>228VAC75% load@>228VAC
    50% load@>190VAC50% load@>190VAC
    PhaseThree phase in, single phase outPhaseThree phase in,single phase out
    Transfer Voltage Range   L-L 380/400/415VACTransfer Voltage Range   L-L 380/400/415VAC
        -Line low transfer190VAC    -Line low transfer190VAC
        -Line low recovery209VAC    -Line low recovery209VAC
        -Line high transfer499VAC    -Line high transfer499VAC
        -Line high recovery486VAC    -Line high recovery486VAC
    Input Current Input Current 
        -Rating(nominal input voltage)16.5A/380V25A/380V33A/380V    -Rating(nominal input voltage)70A/380V
        -Input Power Factor0.99    -Input Power Factor0.99
        -Input current distortion4%    -Input current distortion5%
        -Input Frequency Range40~70Hz    -Input Frequency Range40~70Hz
    OUTPUT OUTPUT 
    Frequency adaptableSettableFrequency adaptableSettable
    Power Power 
        -Power10KVA15KVA20KVA    -Power40KVA
        -Power(kW) 10KW15KW20KW    -Power(kW) 36KW
    Output Voltage Output Voltage 
        -Waveform(Bat. Mode)Pure Sine Wave    -Nominal voltageL-N 220VAC/230VAC/240VAC,  200VAC/208VAC(PF=0.8)
        -Nominal voltageL-N 220VAC/230VAC/240VAC,  200VAC/208VAC(PF=0.9)    -Voltage regulation± 1 %
        -Voltage regulation± 1 %    -Voltage distortion1% THD, linear load        
        -Voltage distortion1% THD, linear load        3% THD, non linear load
    3% THD, non linear loadOutput Frequency 
    Output Frequency     -Synchronization range±5Hz default, ±1Hz,±2Hz,±3Hz,±4Hz,±5Hz settable
        -Synchronization range±5Hz default, settable    -Battery mode(50±0.1) Hz
        -Battery mode(50±0.1) Hz defaultBypass 
    Transfer Time Input modeDual input Alternative common input
        -Line mode to battery mode0ms    -Bypss voltage rangeupper limit:10%/15%/20%/25%@220VAC                                                           lower limit:10%/15%/20%@230VAC                                                               upper limit:10%/15%@240VAC                                                                   lower limit:10%/20%/30%/40%
        -Inverter to bypass0ms    -Bypss frequency rangesettable: ±1Hz,±2Hz,±3Hz,±4Hz,±5Hz; default: ±5Hz 
    Efficiency     -Bypass overload capacityless than 125%: long time running                                                                   126% to 130% :Shutdown in 5 mins                                                           131% to 150% :Shutdown in 1 mins                                                                > 150%  :Shutdown in 200 ms
        -Line mode with battery full charged94%@100% load, 94.5%@70% load94.2%@100% load, 95%@70% load94.2%@100% load, 95%@50% loadTransfer Time 
        -ECO mode98.0%    -Line mode to battery mode0ms
    Noise(1m away) <55dB<62dB<62dB    -Inverter to bypass0ms
    Overload Capability(Inverter)105% to 110% : Transfer to bypass after 10 mins.Efficiency 
    111% to 125% : Transfer to bypass after 1 mins.    -Line mode with battery full charged94%@100% load, 94.5%@70% load
    126% to 150%: Transfer to bypass after 30s    -ECO mode98.0%
    Overload Capability (Bypass Mode)less than 125%: long time runningOverload Capability(Inverter)105% to 110% : Transfer to bypass after 10 mins.
     126% to 130% :Shutdown in 5 mins111% to 125% : Transfer to bypass after 1 mins.
     131% to 150% :Shutdown in 1 mins126% to 150%: Transfer to bypass after 30s
    > 150%  :Shutdown in 200 msNoise(1m away)65dB @ 100% load, 62dB @ 45% load
    BATTERY Crest Factor3:1
    Quantity16-20PCS settable16-20PCS settable16-20PCS settableBattery 
    DC Voltage192VDC default, settableDC voltage±240VDC
    Charger ChargerDigital charger
        -Charging current (max)5A max,settable5A max,settable5A max,settable    -Charging current (max)20% *output power
        -Float Charging Voltage2.25V/cell default, setttable via softwareDisplayLED + color touch LCD
        -Boost Charging Voltage2.25V/cell default, setttable via softwareInterfaceStandard:RS232, RS485, USB,dry contact
    Optional: SNMP,AS/400
    Indicator & Alarm Altitude<1000m, within 1000m to 2000m, power derate 1% for every 100m rise
        -DisplayLED+LCDWorking Enviroment 
    Inteface     -storage -40~70
        -Smart RS232Standard Cable support INVT Power Monitor Software    -working0~40, huminity 95% non condesation, attitude<1500m (@full load)
        -EPONC, NO settable, forbidden defaultMechanical 
        -RS485(option)Installed in the intelligent slot    -WDH (mm)600*980*950
        -SNMP(option)Power Managment from SNMP Manager and Web Browser    -Net Weight (KG)170
    Option ColorBlack default
        -Intelligent KitsDB9 port, dry contact    
        -parallel4 units paralleled    
        -Super charger (12A)digitally controlled, 4-steps charge, settable    
        -USBB-type USB port    
        -SNMP KitsPluggable type    
    Working Enviroment     
        -storage -40~70    
        -working0~40, huminity 95% non condesation, attitude<3000m (@full load)    
    Mechanical     
        -WDH (mm)190*553*336190*542*500    
        -Net Weight (kg)1826    
        -Package Weight (kg)2030    
        -Rack / TowerTower    
    ColorBlack default    
  •  

  • Brochure of HT31 Series Tower Online UPS 10-40kVA (220V230V240V).pdf   

Features

Specifications

Certification

Download

Common features:

 

● Full protection of overvoltage, circuit short and over temperature

 

● Auto fan speed adjustment

 

● Abundant interface:RS232, USB, SNMP, Intelligent Card

 

● Parallel up to 4 units

 

Unique features:

 

● Output PF=1

 

● Small size with higher power density

 

● Digital Charger, adjustable from 1A to 5A

 

● 12A charger for option, charging for large capacity batteries

 

 HT3110XLHT3115XLHT3120XL HT3140L
INPUT INPUT 
Cold StartYES
Default output frequency will be 50Hz or settable
  
Acceptable Input VoltageL-L 190VAC~499VACAcceptable Input VoltageL-L 190VAC~499VAC
 100% load@>305VAC 100% load@>305VAC
90% load@>266VAC90% load@>266VAC
75% load@>228VAC75% load@>228VAC
50% load@>190VAC50% load@>190VAC
PhaseThree phase in, single phase outPhaseThree phase in,single phase out
Transfer Voltage Range   L-L 380/400/415VACTransfer Voltage Range   L-L 380/400/415VAC
    -Line low transfer190VAC    -Line low transfer190VAC
    -Line low recovery209VAC    -Line low recovery209VAC
    -Line high transfer499VAC    -Line high transfer499VAC
    -Line high recovery486VAC    -Line high recovery486VAC
Input Current Input Current 
    -Rating(nominal input voltage)16.5A/380V25A/380V33A/380V    -Rating(nominal input voltage)70A/380V
    -Input Power Factor0.99    -Input Power Factor0.99
    -Input current distortion4%    -Input current distortion5%
    -Input Frequency Range40~70Hz    -Input Frequency Range40~70Hz
OUTPUT OUTPUT 
Frequency adaptableSettableFrequency adaptableSettable
Power Power 
    -Power10KVA15KVA20KVA    -Power40KVA
    -Power(kW) 10KW15KW20KW    -Power(kW) 36KW
Output Voltage Output Voltage 
    -Waveform(Bat. Mode)Pure Sine Wave    -Nominal voltageL-N 220VAC/230VAC/240VAC,  200VAC/208VAC(PF=0.8)
    -Nominal voltageL-N 220VAC/230VAC/240VAC,  200VAC/208VAC(PF=0.9)    -Voltage regulation± 1 %
    -Voltage regulation± 1 %    -Voltage distortion1% THD, linear load        
    -Voltage distortion1% THD, linear load        3% THD, non linear load
3% THD, non linear loadOutput Frequency 
Output Frequency     -Synchronization range±5Hz default, ±1Hz,±2Hz,±3Hz,±4Hz,±5Hz settable
    -Synchronization range±5Hz default, settable    -Battery mode(50±0.1) Hz
    -Battery mode(50±0.1) Hz defaultBypass 
Transfer Time Input modeDual input Alternative common input
    -Line mode to battery mode0ms    -Bypss voltage rangeupper limit:10%/15%/20%/25%@220VAC                                                           lower limit:10%/15%/20%@230VAC                                                               upper limit:10%/15%@240VAC                                                                   lower limit:10%/20%/30%/40%
    -Inverter to bypass0ms    -Bypss frequency rangesettable: ±1Hz,±2Hz,±3Hz,±4Hz,±5Hz; default: ±5Hz 
Efficiency     -Bypass overload capacityless than 125%: long time running                                                                   126% to 130% :Shutdown in 5 mins                                                           131% to 150% :Shutdown in 1 mins                                                                > 150%  :Shutdown in 200 ms
    -Line mode with battery full charged94%@100% load, 94.5%@70% load94.2%@100% load, 95%@70% load94.2%@100% load, 95%@50% loadTransfer Time 
    -ECO mode98.0%    -Line mode to battery mode0ms
Noise(1m away) <55dB<62dB<62dB    -Inverter to bypass0ms
Overload Capability(Inverter)105% to 110% : Transfer to bypass after 10 mins.Efficiency 
111% to 125% : Transfer to bypass after 1 mins.    -Line mode with battery full charged94%@100% load, 94.5%@70% load
126% to 150%: Transfer to bypass after 30s    -ECO mode98.0%
Overload Capability (Bypass Mode)less than 125%: long time runningOverload Capability(Inverter)105% to 110% : Transfer to bypass after 10 mins.
 126% to 130% :Shutdown in 5 mins111% to 125% : Transfer to bypass after 1 mins.
 131% to 150% :Shutdown in 1 mins126% to 150%: Transfer to bypass after 30s
> 150%  :Shutdown in 200 msNoise(1m away)65dB @ 100% load, 62dB @ 45% load
BATTERY Crest Factor3:1
Quantity16-20PCS settable16-20PCS settable16-20PCS settableBattery 
DC Voltage192VDC default, settableDC voltage±240VDC
Charger ChargerDigital charger
    -Charging current (max)5A max,settable5A max,settable5A max,settable    -Charging current (max)20% *output power
    -Float Charging Voltage2.25V/cell default, setttable via softwareDisplayLED + color touch LCD
    -Boost Charging Voltage2.25V/cell default, setttable via softwareInterfaceStandard:RS232, RS485, USB,dry contact
Optional: SNMP,AS/400
Indicator & Alarm Altitude<1000m, within 1000m to 2000m, power derate 1% for every 100m rise
    -DisplayLED+LCDWorking Enviroment 
Inteface     -storage -40~70
    -Smart RS232Standard Cable support INVT Power Monitor Software    -working0~40, huminity 95% non condesation, attitude<1500m (@full load)
    -EPONC, NO settable, forbidden defaultMechanical 
    -RS485(option)Installed in the intelligent slot    -WDH (mm)600*980*950
    -SNMP(option)Power Managment from SNMP Manager and Web Browser    -Net Weight (KG)170
Option ColorBlack default
    -Intelligent KitsDB9 port, dry contact    
    -parallel4 units paralleled    
    -Super charger (12A)digitally controlled, 4-steps charge, settable    
    -USBB-type USB port    
    -SNMP KitsPluggable type    
Working Enviroment     
    -storage -40~70    
    -working0~40, huminity 95% non condesation, attitude<3000m (@full load)    
Mechanical     
    -WDH (mm)190*553*336190*542*500    
    -Net Weight (kg)1826    
    -Package Weight (kg)2030    
    -Rack / TowerTower    
ColorBlack default    

 

Related Application Cases

Related Products

HR31 Series Rack Online UPS 15-20kVA (220V/230V/240V)

The series 3:1 Rack Online UPS is online double-conversion UPS with full DSP control technology. With high input and output power factor, self-adjusting output frequency and network management. The series has 15kVA, 20kVA can be chosen.

HR11 Series Rack Online UPS 1-10kVA (220V/230V/240V)

The series 1:1 Rack Online UPS is the ideal choice for small data center. It supports in-built battery. And the 6kVA and 10kVA rack UPS of this series apply the advanced 3 level of technology, compatible with complicated load. The series has 1kVA, 2kVA, 3kVA, 6kVA, 10 kVA can be chosen.

HTC11 Series Tower Online UPS 1-3kVA 2.0 (220V/230V/240V)

This series tower UPS is the 2.0 version of HT11 1-3kVA, which is to meet the requirements for energy conservation and emission reduction of the markets, compared with the old one, it has a smaller size, better performance, and more competitive price and quality! its power ranges from 1kVA to 3kVA, This product can be widely used, such as small data centers, bank branches, telecom business halls, office buildings, and various edge computing scenarios.

HT11 Series Tower Online UPS 6-20kVA (220V/230V/240V)

This series tower online UPS contain a standard model with built-in batteries and a long backup model.Smaller size with higher power density, double conversion online UPS with fully DSP controlled technology,this series is a perfect choice for computers, telecommunication equipment and other sensitive devices. The series has 6kVA, 10kVA, 15kVA, 20kVA can be chosen.