HT31 Series Tower Online UPS 10-40kVA (220V/230V/240V)

The series 3:1 Tower Online UPS is double conversion online UPS with fully DSP controlled technology. it provides 12A charger for option, and the digital charger can adjust from 1A to 5A. It’s a perfect choice for computers, telecommunication equipments and other sensitive devices. The series has 10kVA, 15kVA, 20kVA, 40kVA can be chosen.

Email Us
  • Product description
  • Features
  • Specifications
  • Application Case
  • Download
    • Commodity name: HT31 Series Tower Online UPS 10-40kVA (220V/230V/240V)
    • Commodity ID: 1063517153245417472

    The series 3:1 Tower Online UPS is double conversion online UPS with fully DSP controlled technology. it provides 12A charger for option, and the digital charger can adjust from 1A to 5A. It’s a perfect choice for computers, telecommunication equipments and other sensitive devices. The series has 10kVA, 15kVA, 20kVA, 40kVA can be chosen.

    The series 3:1 Tower Online UPS  is double conversion online UPS with fully DSP controlled technology. it provides 12A charger for option, and the digital charger can adjust from 1A to 5A. It’s a perfect choice for computers, telecommunication equipments and other sensitive devices. The series has 10kVA, 15kVA, 20kVA, 40kVA can be chosen. ( watch the introduction video on YouTube )

  • Common features:

     

    ● Full protection of overvoltage, circuit short and over temperature

     

    ● Auto fan speed adjustment

     

    ● Abundant interface:RS232, USB, SNMP, Intelligent Card

     

    ● Parallel up to 4 units

     

    Unique features:

     

    ● Output PF=1

     

    ● Small size with higher power density

     

    ● Digital Charger, adjustable from 1A to 5A

     

    ● 12A charger for option, charging for large capacity batteries

     

  •   HT3110XL HT3115XL HT3120XL   HT3140L
    INPUT   INPUT  
    Cold Start YES
    Default output frequency will be 50Hz or settable
       
    Acceptable Input Voltage L-L 190VAC~499VAC Acceptable Input Voltage L-L 190VAC~499VAC
      100% load@>305VAC   100% load@>305VAC
    90% load@>266VAC 90% load@>266VAC
    75% load@>228VAC 75% load@>228VAC
    50% load@>190VAC 50% load@>190VAC
    Phase Three phase in, single phase out Phase Three phase in,single phase out
    Transfer Voltage Range    L-L 380/400/415VAC Transfer Voltage Range    L-L 380/400/415VAC
        -Line low transfer 190VAC     -Line low transfer 190VAC
        -Line low recovery 209VAC     -Line low recovery 209VAC
        -Line high transfer 499VAC     -Line high transfer 499VAC
        -Line high recovery 486VAC     -Line high recovery 486VAC
    Input Current   Input Current  
        -Rating(nominal input voltage) 16.5A/380V 25A/380V 33A/380V     -Rating(nominal input voltage) 70A/380V
        -Input Power Factor 0.99     -Input Power Factor 0.99
        -Input current distortion 4%     -Input current distortion 5%
        -Input Frequency Range 40~70Hz     -Input Frequency Range 40~70Hz
    OUTPUT   OUTPUT  
    Frequency adaptable Settable Frequency adaptable Settable
    Power   Power  
        -Power 10KVA 15KVA 20KVA     -Power 40KVA
        -Power(kW)  10KW 15KW 20KW     -Power(kW)  36KW
    Output Voltage   Output Voltage  
        -Waveform(Bat. Mode) Pure Sine Wave     -Nominal voltage L-N 220VAC/230VAC/240VAC,  200VAC/208VAC(PF=0.8)
        -Nominal voltage L-N 220VAC/230VAC/240VAC,  200VAC/208VAC(PF=0.9)     -Voltage regulation ± 1 %
        -Voltage regulation ± 1 %     -Voltage distortion 1% THD, linear load        
        -Voltage distortion 1% THD, linear load         3% THD, non linear load
    3% THD, non linear load Output Frequency  
    Output Frequency       -Synchronization range ±5Hz default, ±1Hz,±2Hz,±3Hz,±4Hz,±5Hz settable
        -Synchronization range ±5Hz default, settable     -Battery mode (50±0.1) Hz
        -Battery mode (50±0.1) Hz default Bypass  
    Transfer Time   Input mode Dual input Alternative common input
        -Line mode to battery mode 0ms     -Bypss voltage range upper limit:10%/15%/20%/25%@220VAC                                                           lower limit:10%/15%/20%@230VAC                                                               upper limit:10%/15%@240VAC                                                                   lower limit:10%/20%/30%/40%
        -Inverter to bypass 0ms     -Bypss frequency range settable: ±1Hz,±2Hz,±3Hz,±4Hz,±5Hz; default: ±5Hz 
    Efficiency       -Bypass overload capacity less than 125%: long time running                                                                   126% to 130% :Shutdown in 5 mins                                                           131% to 150% :Shutdown in 1 mins                                                                > 150%  :Shutdown in 200 ms
        -Line mode with battery full charged 94%@100% load, 94.5%@70% load 94.2%@100% load, 95%@70% load 94.2%@100% load, 95%@50% load Transfer Time  
        -ECO mode 98.0%     -Line mode to battery mode 0ms
    Noise(1m away)  <55dB <62dB <62dB     -Inverter to bypass 0ms
    Overload Capability(Inverter) 105% to 110% : Transfer to bypass after 10 mins. Efficiency  
    111% to 125% : Transfer to bypass after 1 mins.     -Line mode with battery full charged 94%@100% load, 94.5%@70% load
    126% to 150%: Transfer to bypass after 30s     -ECO mode 98.0%
    Overload Capability (Bypass Mode) less than 125%: long time running Overload Capability(Inverter) 105% to 110% : Transfer to bypass after 10 mins.
     126% to 130% :Shutdown in 5 mins 111% to 125% : Transfer to bypass after 1 mins.
     131% to 150% :Shutdown in 1 mins 126% to 150%: Transfer to bypass after 30s
    > 150%  :Shutdown in 200 ms Noise(1m away) 65dB @ 100% load, 62dB @ 45% load
    BATTERY   Crest Factor 3:1
    Quantity 16-20PCS settable 16-20PCS settable 16-20PCS settable Battery  
    DC Voltage 192VDC default, settable DC voltage ±240VDC
    Charger   Charger Digital charger
        -Charging current (max) 5A max,settable 5A max,settable 5A max,settable     -Charging current (max) 20% *output power
        -Float Charging Voltage 2.25V/cell default, setttable via software Display LED + color touch LCD
        -Boost Charging Voltage 2.25V/cell default, setttable via software Interface Standard:RS232, RS485, USB,dry contact
    Optional: SNMP,AS/400
    Indicator & Alarm   Altitude <1000m, within 1000m to 2000m, power derate 1% for every 100m rise
        -Display LED+LCD Working Enviroment  
    Inteface       -storage  -40~70
        -Smart RS232 Standard Cable support INVT Power Monitor Software     -working 0~40, huminity 95% non condesation, attitude<1500m (@full load)
        -EPO NC, NO settable, forbidden default Mechanical  
        -RS485(option) Installed in the intelligent slot     -WDH (mm) 600*980*950
        -SNMP(option) Power Managment from SNMP Manager and Web Browser     -Net Weight (KG) 170
    Option   Color Black default
        -Intelligent Kits DB9 port, dry contact        
        -parallel 4 units paralleled        
        -Super charger (12A) digitally controlled, 4-steps charge, settable        
        -USB B-type USB port        
        -SNMP Kits Pluggable type        
    Working Enviroment          
        -storage  -40~70        
        -working 0~40, huminity 95% non condesation, attitude<3000m (@full load)        
    Mechanical          
        -WDH (mm) 190*553*336 190*542*500        
        -Net Weight (kg) 18 26        
        -Package Weight (kg) 20 30        
        -Rack / Tower Tower        
    Color Black default        
  •  

    The Fengcheng to Meili,500 kV Yangtze River Leap Project

     

    Caofeidian Port Container Wharf (located in Tangshan city Hebei Province, China)

     

    SGCC of Wuyi County project

     

    Yongrong Building Marketing Center project

Features

Specifications

Application Case

Download

Common features:

 

● Full protection of overvoltage, circuit short and over temperature

 

● Auto fan speed adjustment

 

● Abundant interface:RS232, USB, SNMP, Intelligent Card

 

● Parallel up to 4 units

 

Unique features:

 

● Output PF=1

 

● Small size with higher power density

 

● Digital Charger, adjustable from 1A to 5A

 

● 12A charger for option, charging for large capacity batteries

 

  HT3110XL HT3115XL HT3120XL   HT3140L
INPUT   INPUT  
Cold Start YES
Default output frequency will be 50Hz or settable
   
Acceptable Input Voltage L-L 190VAC~499VAC Acceptable Input Voltage L-L 190VAC~499VAC
  100% load@>305VAC   100% load@>305VAC
90% load@>266VAC 90% load@>266VAC
75% load@>228VAC 75% load@>228VAC
50% load@>190VAC 50% load@>190VAC
Phase Three phase in, single phase out Phase Three phase in,single phase out
Transfer Voltage Range    L-L 380/400/415VAC Transfer Voltage Range    L-L 380/400/415VAC
    -Line low transfer 190VAC     -Line low transfer 190VAC
    -Line low recovery 209VAC     -Line low recovery 209VAC
    -Line high transfer 499VAC     -Line high transfer 499VAC
    -Line high recovery 486VAC     -Line high recovery 486VAC
Input Current   Input Current  
    -Rating(nominal input voltage) 16.5A/380V 25A/380V 33A/380V     -Rating(nominal input voltage) 70A/380V
    -Input Power Factor 0.99     -Input Power Factor 0.99
    -Input current distortion 4%     -Input current distortion 5%
    -Input Frequency Range 40~70Hz     -Input Frequency Range 40~70Hz
OUTPUT   OUTPUT  
Frequency adaptable Settable Frequency adaptable Settable
Power   Power  
    -Power 10KVA 15KVA 20KVA     -Power 40KVA
    -Power(kW)  10KW 15KW 20KW     -Power(kW)  36KW
Output Voltage   Output Voltage  
    -Waveform(Bat. Mode) Pure Sine Wave     -Nominal voltage L-N 220VAC/230VAC/240VAC,  200VAC/208VAC(PF=0.8)
    -Nominal voltage L-N 220VAC/230VAC/240VAC,  200VAC/208VAC(PF=0.9)     -Voltage regulation ± 1 %
    -Voltage regulation ± 1 %     -Voltage distortion 1% THD, linear load        
    -Voltage distortion 1% THD, linear load         3% THD, non linear load
3% THD, non linear load Output Frequency  
Output Frequency       -Synchronization range ±5Hz default, ±1Hz,±2Hz,±3Hz,±4Hz,±5Hz settable
    -Synchronization range ±5Hz default, settable     -Battery mode (50±0.1) Hz
    -Battery mode (50±0.1) Hz default Bypass  
Transfer Time   Input mode Dual input Alternative common input
    -Line mode to battery mode 0ms     -Bypss voltage range upper limit:10%/15%/20%/25%@220VAC                                                           lower limit:10%/15%/20%@230VAC                                                               upper limit:10%/15%@240VAC                                                                   lower limit:10%/20%/30%/40%
    -Inverter to bypass 0ms     -Bypss frequency range settable: ±1Hz,±2Hz,±3Hz,±4Hz,±5Hz; default: ±5Hz 
Efficiency       -Bypass overload capacity less than 125%: long time running                                                                   126% to 130% :Shutdown in 5 mins                                                           131% to 150% :Shutdown in 1 mins                                                                > 150%  :Shutdown in 200 ms
    -Line mode with battery full charged 94%@100% load, 94.5%@70% load 94.2%@100% load, 95%@70% load 94.2%@100% load, 95%@50% load Transfer Time  
    -ECO mode 98.0%     -Line mode to battery mode 0ms
Noise(1m away)  <55dB <62dB <62dB     -Inverter to bypass 0ms
Overload Capability(Inverter) 105% to 110% : Transfer to bypass after 10 mins. Efficiency  
111% to 125% : Transfer to bypass after 1 mins.     -Line mode with battery full charged 94%@100% load, 94.5%@70% load
126% to 150%: Transfer to bypass after 30s     -ECO mode 98.0%
Overload Capability (Bypass Mode) less than 125%: long time running Overload Capability(Inverter) 105% to 110% : Transfer to bypass after 10 mins.
 126% to 130% :Shutdown in 5 mins 111% to 125% : Transfer to bypass after 1 mins.
 131% to 150% :Shutdown in 1 mins 126% to 150%: Transfer to bypass after 30s
> 150%  :Shutdown in 200 ms Noise(1m away) 65dB @ 100% load, 62dB @ 45% load
BATTERY   Crest Factor 3:1
Quantity 16-20PCS settable 16-20PCS settable 16-20PCS settable Battery  
DC Voltage 192VDC default, settable DC voltage ±240VDC
Charger   Charger Digital charger
    -Charging current (max) 5A max,settable 5A max,settable 5A max,settable     -Charging current (max) 20% *output power
    -Float Charging Voltage 2.25V/cell default, setttable via software Display LED + color touch LCD
    -Boost Charging Voltage 2.25V/cell default, setttable via software Interface Standard:RS232, RS485, USB,dry contact
Optional: SNMP,AS/400
Indicator & Alarm   Altitude <1000m, within 1000m to 2000m, power derate 1% for every 100m rise
    -Display LED+LCD Working Enviroment  
Inteface       -storage  -40~70
    -Smart RS232 Standard Cable support INVT Power Monitor Software     -working 0~40, huminity 95% non condesation, attitude<1500m (@full load)
    -EPO NC, NO settable, forbidden default Mechanical  
    -RS485(option) Installed in the intelligent slot     -WDH (mm) 600*980*950
    -SNMP(option) Power Managment from SNMP Manager and Web Browser     -Net Weight (KG) 170
Option   Color Black default
    -Intelligent Kits DB9 port, dry contact        
    -parallel 4 units paralleled        
    -Super charger (12A) digitally controlled, 4-steps charge, settable        
    -USB B-type USB port        
    -SNMP Kits Pluggable type        
Working Enviroment          
    -storage  -40~70        
    -working 0~40, huminity 95% non condesation, attitude<3000m (@full load)        
Mechanical          
    -WDH (mm) 190*553*336 190*542*500        
    -Net Weight (kg) 18 26        
    -Package Weight (kg) 20 30        
    -Rack / Tower Tower        
Color Black default        

Related Application Cases

Related Products

HR31 Series Rack Online UPS 15-20kVA (220V/230V/240V)

The series 3:1 Rack Online UPS is online double-conversion UPS with full DSP control technology. With high input and output power factor, self-adjusting output frequency and network management. The series has 15kVA, 20kVA can be chosen.

BU Series Offline UPS 600-3000VA

The series offline UPS is the ideal choice for various complex power environments such as residential, tertiary industry and industrial fields. The series has the most advanced DSP control technology which can protect the sensitive device from utility fail, over voltage, surges, transients, spikes and other electrical abnormalities.

HR11 Series Rack Online UPS 1-10kVA (220V/230V/240V)

The series 1:1 Rack Online UPS is the ideal choice for small data center. It supports in-built battery. And the 6kVA and 10kVA rack UPS of this series apply the advanced 3 level of technology, compatible with complicated load. The series has 1kVA, 2kVA, 3kVA, 6kVA, 10 kVA can be chosen.

HTC11 Series Tower Online UPS 1-3kVA 2.0 (220V/230V/240V)

This series tower UPS is the 2.0 version of HT11 1-3kVA, which is to meet the requirements for energy conservation and emission reduction of the markets, compared with the old one, it has a smaller size, better performance, and more competitive price and quality! its power ranges from 1kVA to 3kVA, This product can be widely used, such as small data centers, bank branches, telecom business halls, office buildings, and various edge computing scenarios.