Inverter Small Room Precision Cooling System(5.5-32kW)

The cooling system is tailor-made for small IT room and equipment room. Equipped with EC fans, compared with traditional fans, the energy saving is more than 30%. Adopts the GMCC frequency conversion compressor which can match the output according to the demand. It supports checking 30 days of temperature and humidity curve data. ( Watch the introduction video on YouTube )


Email Us
  • Product description
  • Features
  • Specifications
  • Certification
  • Download
    • Commodity name: Inverter Small Room Precision Cooling System(5.5-32kW)
    • Commodity ID: 1063516633973805056

    The cooling system is tailor-made for small IT room and equipment room. Equipped with EC fans, compared with traditional fans, the energy saving is more than 30%. Adopts the GMCC frequency conversion compressor which can match the output according to the demand. It supports checking 30 days of temperature and humidity curve data.

    The cooling system is tailor-made for small IT room and equipment room. Equipped with EC fans, compared with traditional fans, the energy saving is more than 30%. Adopts the GMCC frequency conversion compressor which can match the output according to the demand. It supports checking 30 days of temperature and humidity curve data. ( Watch the introduction video on YouTube )

  • Energy efficient

    ● Large air volume, small enthalpy difference, high sensible heat ratio design, to meet the temperature control needs of the server room. 
    ● High energy-efficient compressor with electronic expansion valve as standard for fast response and more accurate flow adjustment. 
    ● High efficiency backward tilting centrifugal fan with low energy consumption and high air volume to ensure uniform temperature and humidity distribution in the server room. 
    ● The use of high-efficiency internally threaded copper tubes and hydrophilic layer-plated open-window aluminum fin evaporators for higher heat transfer efficiency. 
    ● Outdoor fan with infinitely adjustable speed control, matching condensing pressure operation, energy saving and noise reduction. 
    ● Standard with electrode humidifier, higher humidification efficiency and wider application range.


    Safe and reliable

    ● Use of rigorously certified, high-quality devices to enhance reliability. 
    ● Products are subjected to rigorous and repeated testing and verification, with high standards required for high quality delivery. 
    ● 365 x 24 hours non-stop operation, long life design and low maintenance costs. 
    ● Ultra-wide grid adaptability to avoid frequent start/stop of air conditioners. 
    ● Highly efficient and environmentally friendly refrigerant R410A as standard. 
    ● Threaded quick coupling design for no welding on site.


    Intelligent control

    ● 4.3-inch true color touch screen, multi-level password authority, system self- test diagnostic function, more intelligent; 
    ● Comprehensive monitoring and display of power supply voltage, frequency, phase sequence, cooling capacity, air volume, temperature and humidity curve and other key information, real-time control of the normal state of the system; 
    ● Up to 64 air conditioners can be rotated patrol group control to achieve scheduled rotation, fault rotation, cascading, demand synchronization, anti- competitive operation, etc;

    ● Support power-on self-start and timer on/off functions, easy to manage air conditioners;

    ● Local storage of not less than 1000 history records, easy to view and trace; 
    ● Standard RS485 interface, support optional SNMP interface.


    Customizable

    ● Standard with electrode humidifier, support optional wet film humidifier; 
    ● 100% full frontal maintenance and more flexible installation; 
    ● Support optional upper pipe / upper drainage to meet the needs of different scenarios;

    ● Support AC/EC fans optional according to actual needs; 
    ● Optional dual power input; 
    ● A variety of air supply methods to meet a variety of applications; 
    ● Optional phase tolerance function to better protect the power of air conditioners.

  •  

    Unit

    VCA005/VCP007-

    O

    VCA007/VCP010-

    O

    VCA012/VCP018-

    O

    VCA017/VCP024-

    O

    VCA020/VCP028-

    O

    Type

    -

    KF

    Constant 

    Temp&Hum

    KF

    Constant 

    Temp&Hum

    KF

    Constant 

    Temp&Hum

    KF

    Constant 

    Temp&Hum

    KF

    Constant 

    Temp&Hum

    cooling 

    capacity

    kW

    5.5

    5.5

    7.5

    7.5

    12.5

    12.5

    17.0

    17.0

    20.5

    20.5

    SHR

    kW

    0.91

    0.91

    0.9

    0.9

    0.9

    0.9

    0.93

    0.93

    0.92

    0.92

    Air volume

    m³/h

    2000

    2300

    3200

    5000

    5500

    Heating 

    capacity

    kW

    -

    3.0

    -

    3.0

    -

    3.0

    -

    6.0

    -

    6.0

    Humidification 

    capacity

    kg/h

    -

    3.0

    -

    3.0

    -

    3.0

    -

    3.0 

    -

    3.0 

    Compressor

    -

    Fixed-frequency

    Power supply

    V

    220V~50Hz 1PH

    380V~50Hz 3PH

    Full load 

    current

    A

    10.5

    23.0

    14.9

    25

    10.8

    21.9

    14.3

    25.6

    14.6

    26.1

    Gas pipe size

    mm

    9.52

    9.52

    9.52

    9.52

    9.52

    9.52

    12.7

    12.7

    12.7

    12.7

    Liquid pipe 

    size

    mm

    12.7

    12.7

    12.7

    12.7

    12.7

    12.7

    19.05

    19.05

    19.05

    19.05

    Weight

    kg

    62

    65

    100

    120

    130

  • Small Room AC product introduction20240307-208V.pdf   

Features

Specifications

Certification

Download

Energy efficient

● Large air volume, small enthalpy difference, high sensible heat ratio design, to meet the temperature control needs of the server room. 
● High energy-efficient compressor with electronic expansion valve as standard for fast response and more accurate flow adjustment. 
● High efficiency backward tilting centrifugal fan with low energy consumption and high air volume to ensure uniform temperature and humidity distribution in the server room. 
● The use of high-efficiency internally threaded copper tubes and hydrophilic layer-plated open-window aluminum fin evaporators for higher heat transfer efficiency. 
● Outdoor fan with infinitely adjustable speed control, matching condensing pressure operation, energy saving and noise reduction. 
● Standard with electrode humidifier, higher humidification efficiency and wider application range.


Safe and reliable

● Use of rigorously certified, high-quality devices to enhance reliability. 
● Products are subjected to rigorous and repeated testing and verification, with high standards required for high quality delivery. 
● 365 x 24 hours non-stop operation, long life design and low maintenance costs. 
● Ultra-wide grid adaptability to avoid frequent start/stop of air conditioners. 
● Highly efficient and environmentally friendly refrigerant R410A as standard. 
● Threaded quick coupling design for no welding on site.


Intelligent control

● 4.3-inch true color touch screen, multi-level password authority, system self- test diagnostic function, more intelligent; 
● Comprehensive monitoring and display of power supply voltage, frequency, phase sequence, cooling capacity, air volume, temperature and humidity curve and other key information, real-time control of the normal state of the system; 
● Up to 64 air conditioners can be rotated patrol group control to achieve scheduled rotation, fault rotation, cascading, demand synchronization, anti- competitive operation, etc;

● Support power-on self-start and timer on/off functions, easy to manage air conditioners;

● Local storage of not less than 1000 history records, easy to view and trace; 
● Standard RS485 interface, support optional SNMP interface.


Customizable

● Standard with electrode humidifier, support optional wet film humidifier; 
● 100% full frontal maintenance and more flexible installation; 
● Support optional upper pipe / upper drainage to meet the needs of different scenarios;

● Support AC/EC fans optional according to actual needs; 
● Optional dual power input; 
● A variety of air supply methods to meet a variety of applications; 
● Optional phase tolerance function to better protect the power of air conditioners.

 

Unit

VCA005/VCP007-

O

VCA007/VCP010-

O

VCA012/VCP018-

O

VCA017/VCP024-

O

VCA020/VCP028-

O

Type

-

KF

Constant 

Temp&Hum

KF

Constant 

Temp&Hum

KF

Constant 

Temp&Hum

KF

Constant 

Temp&Hum

KF

Constant 

Temp&Hum

cooling 

capacity

kW

5.5

5.5

7.5

7.5

12.5

12.5

17.0

17.0

20.5

20.5

SHR

kW

0.91

0.91

0.9

0.9

0.9

0.9

0.93

0.93

0.92

0.92

Air volume

m³/h

2000

2300

3200

5000

5500

Heating 

capacity

kW

-

3.0

-

3.0

-

3.0

-

6.0

-

6.0

Humidification 

capacity

kg/h

-

3.0

-

3.0

-

3.0

-

3.0 

-

3.0 

Compressor

-

Fixed-frequency

Power supply

V

220V~50Hz 1PH

380V~50Hz 3PH

Full load 

current

A

10.5

23.0

14.9

25

10.8

21.9

14.3

25.6

14.6

26.1

Gas pipe size

mm

9.52

9.52

9.52

9.52

9.52

9.52

12.7

12.7

12.7

12.7

Liquid pipe 

size

mm

12.7

12.7

12.7

12.7

12.7

12.7

19.05

19.05

19.05

19.05

Weight

kg

62

65

100

120

130

Related Application Cases

Related Products

Inverter Large Room Precision Cooling System(25-120kW)

It's modular design, fast and flexible assembly on site without cutting copper tubing, support 100% front maintenance, support web access and email notice, can adapt to outdoor 55℃ high temperature, the 10-inch toch color LCD can meet the 30-day temperature and humidity curve and data display.

In-row Precision Cooling System(12.5-60kW)

Especially suitable for modular or container data centers. The series precision cooling system is configured high-efficiency variable frequency compressor, EC backward inclined centrifugal fan, and full variable frequency design, It's usually installed side by side with the server cabinet, creating an ideal operating environment for the key infrastructure of the data center.

Rack Precision Cooling System(3.7-12.5kW)

It's the special air conditioner for circularly cooling the internal air of the 19-inch server cabinet, provides stable and reliable temperature and humidity regulation services, improves the stability and reliability of all kinds of equipment in IT cabinet, the product can be used with our iSmart and iWit.

Energy Storage System Cooling(7.5-20.5kW)

Special designed for power control equipment, energy storage container, and small data room, help to adjust and control the battery temperature to improve the safety and stability of battery operation. It adopts integrated design, complete isolation from inside and outside, provides IP20 or IP55 protection, suitable for multi-scenario installation.