iSmart Series Integrated Cabinet Solution
iSmart Series Micro & Small Integrated Data Center Solution integrates UPS, air conditioner, power distribution module, monitoring system, temperature and humidity detection, light and access control in a standard 19-inch server cabinet. All equipment is pre-installed and pre-commissioned in the factory. The on-site installation is easy and convenient, which can realize rapid deployment, occupy less area, and comes with remote web interface monitoring function, which can realize remote operation and maintenance of a site. ( watch the introduction video on YouTube )
Email Us
- Product description
- Features
- Specifications
- Application Case
- Download
-
iSmart Series Micro & Small Integrated Data Center Solution integrates UPS, air conditioner, power distribution module, monitoring system, temperature and humidity detection, light and access control in a standard 19-inch server cabinet. All equipment is pre-installed and pre-commissioned in the factory. The on-site installation is easy and convenient, which can realize rapid deployment, occupy less area, and comes with remote web interface monitoring function, which can realize remote operation and maintenance of a site. ( watch the introduction video on YouTube )
-
Safe and reliable
● All components follow domestic and international standardized production standards to ensure product quality.
● Pre-installation, pre-commissioning and other process are controlled at various levels to ensure product installation and
operation safe and reliable.● A single cabinet is a complete system, suitable for various complex scenes (dust, narrow space, no insulation measures, etc.).
● Integrated design, overall delivery, avoid system design problems.
● The emergency cooling fan can delay the channel overheating and reserves time for data backup.
● The cabinet integrates an intelligent monitoring system to ensure the safe and reliable operation of the computer room.
Easy installation and rapid deployment
● Modular design of power distribution, easy installation and maintenance.
● Rack-mounted air conditioner indoor unit, pipe thread connection, easy maintenance.
● The computer room does not need special decoration treatment, and the equipment is ready to use. Installation and commissioning cycle only need 3 hours.
● A single cabinet is a complete system, which can be easily and quickly expanded to 2-3 cabinets side by side.
Efficiency and energy saving
● Proximal refrigeration, high-efficiency power supply, and the overall annual average PUE of single cabinet ≈ 1.30.
● The power distribution, UPS, monitoring, and refrigeration cabinets are integrated to save space.
● Engineering free design, free decoration and wiring, remote operation and maintenance are not on duty, saving TCO.
Intelligent management
● The monitoring system is extensible and compatible with third-party monitoring systems; friendly human-computer interface.
● Support local and remote WEB interface access, SMS alarm function.
-
System
IT rated power
3kVA
Mains
220Vac,50Hz/60Hz
Ambient temperature
0-45℃
Ambient humidity
10-95% (Relative humidity)
IP Class
IP5X
Altitude
1000m, dereating for >1000m
Cabinet
Dimension(W*D*H)
600*1200*2000mm(Without caster)
Space occupation
≤32U
Display
10.1’’ touch screen LCD
Ambient Light
Front RGB three-color ambient light
Lighting method
Front and rear LED
Cable entry
Top and bottom
Access control system
Fingerprint + swipe card(IC&ID) + digital password three in one
Power Supply and Distribution System
Distribution module
Configuration
Main CB: 63A/2P, rack installation, with the indicator of operation
Lightning protection
Class C lightning protection (Standard for 2P, optional for 1P+N)
Height
3U
UPS
Capacity
3kVA/6kVA
Power dstribution
Single phase in and single phase out
Battery
Built-in battery or external battery cabinet
PDU
Normal type
IEC C13*2pcs, 16 ports (13*10A+3*16A)
Intelligent type
Optional for 24 ports
Monitoring System
Supervision system
Intelligent integrated monitoring host
Single cabinet
Single cabinet control module
Eenvironment monitoring
smoke detector*1
Temperature&humidity detector*1
Water leakage detector*1
Webcam(optional)
Infrared detector(optional)
Other detector
SMS alarm (optional)
Emergency Ventilation
Emergency measures
Emergency pop-up door system
Cooling System
Air conditioner
Rack type (Standard for constant temperature)
Rated cooling capacity
3.7kW
Rated power consumption
1.2kW
Rated air volume
700m³/h
Drop height
-5m≤△H≤10m
Mechanical
Package dimensions
720*1338*2230mm
Weight
188kg (without AC, UPS, battery pack)
Cabinet color
Black (RAL9004)
-
Features
Specifications
Application Case
Download
Safe and reliable
● All components follow domestic and international standardized production standards to ensure product quality.
● Pre-installation, pre-commissioning and other process are controlled at various levels to ensure product installation and
operation safe and reliable.
● A single cabinet is a complete system, suitable for various complex scenes (dust, narrow space, no insulation measures, etc.).
● Integrated design, overall delivery, avoid system design problems.
● The emergency cooling fan can delay the channel overheating and reserves time for data backup.
● The cabinet integrates an intelligent monitoring system to ensure the safe and reliable operation of the computer room.
Easy installation and rapid deployment
● Modular design of power distribution, easy installation and maintenance.
● Rack-mounted air conditioner indoor unit, pipe thread connection, easy maintenance.
● The computer room does not need special decoration treatment, and the equipment is ready to use. Installation and commissioning cycle only need 3 hours.
● A single cabinet is a complete system, which can be easily and quickly expanded to 2-3 cabinets side by side.
Efficiency and energy saving
● Proximal refrigeration, high-efficiency power supply, and the overall annual average PUE of single cabinet ≈ 1.30.
● The power distribution, UPS, monitoring, and refrigeration cabinets are integrated to save space.
● Engineering free design, free decoration and wiring, remote operation and maintenance are not on duty, saving TCO.
Intelligent management
● The monitoring system is extensible and compatible with third-party monitoring systems; friendly human-computer interface.
● Support local and remote WEB interface access, SMS alarm function.
System |
IT rated power |
3kVA |
|
Mains |
220Vac,50Hz/60Hz |
||
Ambient temperature |
0-45℃ |
||
Ambient humidity |
10-95% (Relative humidity) |
||
IP Class |
IP5X |
||
Altitude |
1000m, dereating for >1000m |
||
Cabinet |
Dimension(W*D*H) |
600*1200*2000mm(Without caster) |
|
Space occupation |
≤32U |
||
Display |
10.1’’ touch screen LCD |
||
Ambient Light |
Front RGB three-color ambient light |
||
Lighting method |
Front and rear LED |
||
Cable entry |
Top and bottom |
||
Access control system |
Fingerprint + swipe card(IC&ID) + digital password three in one |
||
Power Supply and Distribution System |
Distribution module |
Configuration |
Main CB: 63A/2P, rack installation, with the indicator of operation |
Lightning protection |
Class C lightning protection (Standard for 2P, optional for 1P+N) |
||
Height |
3U |
||
UPS |
Capacity |
3kVA/6kVA |
|
Power dstribution |
Single phase in and single phase out |
||
Battery |
Built-in battery or external battery cabinet |
||
PDU |
Normal type |
IEC C13*2pcs, 16 ports (13*10A+3*16A) |
|
Intelligent type |
Optional for 24 ports |
||
Monitoring System |
Supervision system |
Intelligent integrated monitoring host |
|
Single cabinet |
Single cabinet control module |
||
Eenvironment monitoring |
smoke detector*1 |
||
Temperature&humidity detector*1 |
|||
Water leakage detector*1 |
|||
Webcam(optional) |
|||
Infrared detector(optional) |
|||
Other detector |
SMS alarm (optional) |
||
Emergency Ventilation |
Emergency measures |
Emergency pop-up door system |
|
Cooling System |
Air conditioner |
Rack type (Standard for constant temperature) |
|
Rated cooling capacity |
3.7kW |
||
Rated power consumption |
1.2kW |
||
Rated air volume |
700m³/h |
||
Drop height |
-5m≤△H≤10m |
||
Mechanical |
Package dimensions |
720*1338*2230mm |
|
Weight |
188kg (without AC, UPS, battery pack) |
||
Cabinet color |
Black (RAL9004) |
Related Application Cases
Related Products
iLegend Container Data Center Solution
iLegend series container data center adopts integrated design (All-in-one), meeting the demand of outdoor small and medium-sized data center construction with fast deployment, fast delivery and flexible movement.
iWit Series Medium-Sized Integrated Data Center Solution
The Medium-Sized Integrated Data Center Solution integrates all needed equipment into cabinet with closed hot and cold aisles. The overall area of a single cabinet is 0.84㎡, which is suitable for computer rooms within 20-60㎡. We can provide customers with all options and you can choose according to your needs.