RM Series Rack-Mounted Modular Online UPS 25-200kVA ( 380V/400V/415V )
The series Rack-Mounted Modular Online UPS is high space-saving product for medium data center. It has 150kVA, 200kVA can be chosen, The power module is 2U height, compatible with 19”standard rack cabinet. The UPS can be configured to 3:1, 3:1 and 1:1. saving more than 33% server cabinet space,single module power density reaches 25kW/2U which is 50% higher than the industry mainstream level. Compared with the 10-90kVA UPS, it has higher power density,higher load capacity. ( watch the introduction video on YouTube )
Email Us
- Product description
- Features
- Specifications
- Application Case
- Download
-
The series Rack-Mounted Modular Online UPS is high space-saving product for medium data center. It has 150kVA, 200kVA can be chosen, The power module is 2U height, compatible with 19”standard rack cabinet. The UPS can be configured to 3:1, 3:1 and 1:1. saving more than 33% server cabinet space,single module power density reaches 25kW/2U which is 50% higher than the industry mainstream level. Compared with the 10-90kVA UPS, it has higher power density,higher load capacity. ( watch the introduction video on YouTube )
-
● High Power Density
25kVA power module in 2U height, saving great amount of space, easy for capacity expansion
● Rack Modular Design
Module design, compatible with 19” standard rack cabinet, convenient to be integrated with servers
● Battery Cold Start
UPS can be powered on from the battery without utility
● Friendly Interface
-
MODELRM150/25CRM200/25CSystem Capacity150kVA/150kW200KVA/200kWPower Module Capacity25kVA/25kWNo. of Modules68MainInput3P+N+PERate Voltage380/400/415VAC (line-lin)Rate Frequency50/60HzInput Voltage Range304~478Vac (line-line),full load 228V~304Vac (line-line),derate from 75% to 100% loadInput Frequency Range40Hz~70HzInput PF>0.99Input THDi<3% (100% Linear load)BypassRate Voltage380/400/415VAC (line-line)Rate Frequency50/60HzInput Voltage RangeSettable, Default -40%~+25%Bypass Frequency RangeSettable, ±1Hz, ±3Hz, ±5HzBypass Overload110% for 1 hour;125% for 10min ;150% for min;>150% for 200msOutputRate Voltage380/400/415VAC (line-line)Rate Frequency50/60HzOutput PF1Output THDu<1%? ,Linear load<6% ,Non-linear load( IEC/EN62040-3)Inverter Overload<110%, 1 hour;110%~125%,10 mins;125%~150%,1min;>150%,200msBatteryBattery Number±240VDCCharging Accuracy1%Charging Capacityup to 20% * Output PowerBattery Cold StartYesEfficiencyAC Mode?>96.0%Battery Mode>95.5%SystemDisplayLED + LCD + Touch ScreenInterfaceRS232, RS485,Programmable Dry ContactOptionSNM Card, Parallel,SPDEnvioromentOperation Temperature0 ~ 40 ℃Storage Temperature-40 ~ 70 ℃Ralative Humidity0 ~ 95% Non CondensingNoise (1 meter)65dB @ 100% load, 62dB @ 45% loadPhisical dataModule Dimension W*D*H(mm)436*677*85Module Weight(kg)18Cabinet Dimension W*D*H(mm)485*900*1072482*916*1550Cabinet Weight(kg)140160
-
IDC(Internet Data Center), network servers and workstation, control system, communication system, office, PC etc
Huaibei Daily Newspaper project
Shijiazhuang Hi-tech Industrial Development Zone project
Shanxi Provincial Cancer Hospital project
Cangzhou High-Industrial Artifical Intelligence Science and Technology Industrial Park project
YINFENG BIOLOGICAL GROUP project
Yunnan Airport Group Co., Ltd Lijiang Airport project
Yancheng Yueda 889 Square project
Yongfeng County Public Security Bureau project
The People's Hospital of Maoxian project
Jinzhou Medical University project
Features
Specifications
Application Case
Download
● High Power Density
25kVA power module in 2U height, saving great amount of space, easy for capacity expansion
● Rack Modular Design
Module design, compatible with 19” standard rack cabinet, convenient to be integrated with servers
● Battery Cold Start
UPS can be powered on from the battery without utility
● Friendly Interface
MODEL
|
RM150/25C
|
RM200/25C
|
|||
System Capacity
|
150kVA/150kW
|
200KVA/200kW
|
|||
Power Module Capacity
|
25kVA/25kW
|
||||
No. of Modules
|
6
|
8
|
|||
Main
|
|||||
Input
|
3P+N+PE
|
||||
Rate Voltage
|
380/400/415VAC (line-lin)
|
||||
Rate Frequency
|
50/60Hz
|
||||
Input Voltage Range
|
304~478Vac (line-line),full load 228V~304Vac (line-line),derate from 75% to 100% load
|
||||
Input Frequency Range
|
40Hz~70Hz
|
||||
Input PF
|
>0.99
|
||||
Input THDi
|
<3% (100% Linear load)
|
||||
Bypass
|
|||||
Rate Voltage
|
380/400/415VAC (line-line)
|
||||
Rate Frequency
|
50/60Hz
|
||||
Input Voltage Range
|
Settable, Default -40%~+25%
|
||||
Bypass Frequency Range
|
Settable, ±1Hz, ±3Hz, ±5Hz
|
||||
Bypass Overload
|
110% for 1 hour;125% for 10min ;150% for min;>150% for 200ms
|
||||
Output
|
|||||
Rate Voltage
|
380/400/415VAC (line-line)
|
||||
Rate Frequency
|
50/60Hz
|
||||
Output PF
|
1
|
||||
Output THDu
|
<1%? ,Linear load<6% ,Non-linear load( IEC/EN62040-3)
|
||||
Inverter Overload
|
<110%, 1 hour;110%~125%,10 mins;125%~150%,1min;>150%,200ms
|
||||
Battery
|
|||||
Battery Number
|
±240VDC
|
||||
Charging Accuracy
|
1%
|
||||
Charging Capacity
|
up to 20% * Output Power
|
||||
Battery Cold Start
|
Yes
|
||||
Efficiency
|
|||||
AC Mode?
|
>96.0%
|
||||
Battery Mode
|
>95.5%
|
||||
System
|
|||||
Display
|
LED + LCD + Touch Screen
|
||||
Interface
|
RS232, RS485,Programmable Dry Contact
|
||||
Option
|
SNM Card, Parallel,SPD
|
||||
Envioroment
|
|||||
Operation Temperature
|
0 ~ 40 ℃
|
||||
Storage Temperature
|
-40 ~ 70 ℃
|
||||
Ralative Humidity
|
0 ~ 95% Non Condensing
|
||||
Noise (1 meter)
|
65dB @ 100% load, 62dB @ 45% load
|
||||
Phisical data
|
|||||
Module Dimension W*D*H(mm)
|
436*677*85
|
||||
Module Weight(kg)
|
18
|
||||
Cabinet Dimension W*D*H(mm)
|
485*900*1072
|
482*916*1550
|
|||
Cabinet Weight(kg)
|
140
|
160
|
IDC(Internet Data Center), network servers and workstation, control system, communication system, office, PC etc
Huaibei Daily Newspaper project
Shijiazhuang Hi-tech Industrial Development Zone project
Shanxi Provincial Cancer Hospital project
Cangzhou High-Industrial Artifical Intelligence Science and Technology Industrial Park project
YINFENG BIOLOGICAL GROUP project
Yunnan Airport Group Co., Ltd Lijiang Airport project
Yancheng Yueda 889 Square project
Yongfeng County Public Security Bureau project
The People's Hospital of Maoxian project
Jinzhou Medical University project
Related Application Cases
Related Products
RM Series Rack-Mounted Modular Online UPS 5-20kVA (380V/400V/415V)
It's a single-phase modular UPS that can be configured with up to 6 power modules(maximum 20kVA), 5 groups of battery modules, and optional 10A charging module. It can be flexible configured to 1 phase in and out without deration to satisfy various projects requirements, compatible with all kinds of 19” standard sever cabinet. The whole product is a complete tower modular UPS system, especially suitable for small and medium server rooms.
RM Series In-built Battary Modular Online UPS 20-60kVA (380V/400V/415V)
The series Modular Online UPS is with in-built battery. It can hold 4 groups of 9Ah batteries, a total of 160pcs. Battery package also can be hot-swappable and monitored by the monitor system, easy for maintenance.
RM Series Modular Online UPS 10-90kVA (380V/400V/415V)
The series Rack-Mounted Modular Online UPS is high space-saving product for small and medium data center. It has 90kVA, 60kVA, 45kVA, 40kVA, 30kVA, 20kVA can be chosen, The power module is 2U height, compatible with 19”standard rack cabinet. The UPS can be configured to 3:1, 3:1 and 1:1. saving more than 33% server cabinet space, single module power density reaches 25kW/2U which is 50% higher than the industry mainstream level. Compared with the 10 - 90 kVA UPS, it has higher power density, higher load capacity.
RM Series Modular Online UPS 20-200kVA (380V/400V/415V)
The series Modular Online UPS is high reliability product for small and medium data center. It's the first generation UPS of INVT Power, it provides 60kVA, 120kVA, 200kVA for choosing. Modular IGBT design and isolated air channel ensured the wide adaptable of harsh environment.