Copyright 2018 © Invt Power System(ShenZhen)Co., Ltd.All Rights Reserved  |   粤ICP备10226515号  Powered by  www.300.cn

Products

>
>
>
RM Series Modular Online UPS 25-600kVA (380V/400V/415V)
Page view

RM Series Modular Online UPS 25-600kVA (380V/400V/415V)

没有此类产品
Features
Specifications
Application Case
Summary
Download

Independent LCD for Each Power Module
Each power module has an independent LCD, gives users’ direct overview of status data and alarms in real time.

Friendly Interface
Provide graphical and text based information of alarms, status data, instructions that users can have more friendly and safer operation.

Isolated Air Flow
The dedicated and redundant hot-swappable power modules take the most unique structure design. In this design, the PCB boards and heat-sinkers are in two completely different layers, which allows the UPS run in dusty environments, significantly improving its stability and environmental adaptability.
Cooling air flows in the lower layer, keeping the upper PCB free of dust
One air flow channel ensures fans redundancy, even one fan fails, power module can run normally

Unique Design for High Reliability
Instead of discrete IGBT and SCR components, RM series UPS uses modular IGBT and SCR in Rectifier and Inverter, bringing in extremely high reliability.
All components in one module, less fault points, higher reliability
All components integrated as one modular design, smaller disparity
Less space needed, UPS with compact design and higher power design
Integrated inner thermal sensors display IGBT inner temperature directly

High Density, Modular, Scalable
High power density, footprint for 300kVA is 0.66m², power density 409kW/m², saving valuable data center space
Scalable from 30kVA to 900kVA, max 30 power modules in parallel
Inherently N+X redundant
Hot swappable power module and bypass & monitoring module
Additional charging module, extra charging current 50A×N for long time back up application

Comprehensive Monitoring Management
In each power module, information of critical components is monitored and displayed in real time, giving customers a view of inner status of the system and providing reminder information for maintenance.
Maintenance reminder, running time of capacitors and fans displayed and recorded
Comprehensive temperature monitoring for thermal abnormal detection
Intelligent battery charger for long battery life

Critical Waveform Recording
UPS can record and save the data of the main parameters automatically when faults happen for further analysis.
Can record data information and present as waveform for further analysis
Can easily spot the causes of the failures, avoid future similar faults

Smart Sleep
Smart Sleep function can intelligently make some power modules go to sleep when load is relatively low, improving the efficiency of the remaining power modules and saving customers on power and cooling costs.
Improving efficiency, reducing power and cooling costs Easy setting with just two steps. Customers can select sleep mode and rotation period
Power modules working in rotation, prolong the life time

Self-aging
Self-aging is an advanced function applied in all three phase UPS, self-aging function can test UPS under different load situation without real load, saving more than 90% of energy.
Simulate different load conditions without connecting to any real load, saving 90% of energy On site setting supported, easy for factory testing

Programmable Dry Contacts
Programmable dry contacts are available in all RM and HT33 series UPS. Customers can easily expand or modify the definition of each port.
Abundant options with three inputs and four outputs, all programmable
Easy setting, just pull the drop-down menu and set
Compatible with all the RM and HT33

Corresponding parameter set not found, please add it in property template of background

Mode

RM600/30X

RM300/30X

RM180/30X

Main Input

Grid System

3 Phases + Neutral + Ground

Rated Input Voltage

380/400/415VAC (Line-Line)

Rated Frequency

50/60Hz

Input Voltage Range

304~478Vac (Line-Line),full load;
228V~304Vac (Line-Line),load decrease linearly according to the min phase voltage

Input Frequency Range

40Hz70Hz

Input Power Factor


>0.99

Input Current THDi

<3% (full Linear Load)

Bypass Input

Rated Bypass Voltage

380/400/415VAC (Line-Line)

Rated Frequency

50/60Hz

Bypass Voltage Range

Selectable,  default -20%+15%
Upper limit: +10%, +15%, +20%, +25%; Lower limit: -10%,  -15%, -20%, -30%,  -40%

Bypass Frequency Range

Selectable, ±1Hz, ±3Hz, ±5Hz

Bypass Overload

110% Long term operation; 110%~125% for 5min;
125%~150% for 1min;

Output

Rated Inverter Voltage

380/400/415VAC (Line-Line)

Rated Frequency

50/60Hz

Output Power Factor

0.9

Voltage precision

±1.5%(0-100% linear load)

Transient Response

<5% for step load  (20% - 80% -20%)

Transient recovery

< 30ms for step load (20% - 100% -20%)

Output Voltage THDu

<1% ( linear load);
<6% (non-linear load )according to IEC/EN62040-3

Inverter Overload


110%, 60min;
125%,10min;
150%,1min;
>150%,200ms

Frequency Regulation

50/60Hz±0.1%

Synchronized Range

Settable, ±0.5Hz  ±5Hz, default ±3Hz

Synchronized Slew Rate

Settable, 0.5Hz/s 3Hz/s, default 0.5Hz/s

Battery And Charger

Battery Rate Voltage

±240VDC

Charger Voltage precision

1%

Charger Power

max=20%

Efficiency

Normal Operation

>95%

Battery Operation

>95%

ECO Opetation

>99%

System

Display

10.4” touch colour LCD+LED+Keyboard

Interface

Standard:RS232, RS485, USB,Dry Contact;
Option: SNMP,AS/400

Environmental

Operation Temperature

0  40

Storage Temperature

-40  70

Relative Humidity

0  95% (Non condensing)

Noise (1 meter)

72dB @ 100% load, 68dB @ 45% load

65dB @ 100% load, 62dB @ 45% load

Physical data

Power Module DimensionW*D*H,mm

460*790*134

power Module Weight (kg)

34

Cabinet Dimension(W*D*H,mm

2000*1050*2000

600*1100*2000

600*1100*1600

Cabinet Weigh (kg)

660

220

165

 


The RM series modular UPS provides the most compact footprint of less than 2㎡ with maximum capacity of 900kVA. With best reliability and high performance, it has been leading the domestic market for years.

暂未实现,敬请期待
暂未实现,敬请期待
Previous article